(4) Detaching and refitting the high voltage PWB
Procedure
1. Remove the developing unit (See page 1-5-
11).
2. Remove the drum unit (See page 1-5-12).
3. Remove the cassette (See page 1-5-6).
4. Remove the outer covers (See page 1-5-3).
5. Remove the power source PWB (See page
1-5-22).
6. Turn the printer with the bottom side up.
7. Simplex model: Proceed to the step 12.
Duplex model: Proceed to the step 8.
8. Remove the stop ring.
9. Remove the DU holder.
10. Pull out the DU bush.
11. Remove the DU cover assembly.
Figure 1-5-34
DU cover assembly
Figure 1-5-35
Stop ring
DU holder
DU bush
2H5/2HS