Shutdown - Power LED Blinks continously

If the power LED blinks continously, the problem is eith
a
n open thermal circuit breaker located above the lamp housing. Refer to figure 38.
Both switches can be checked at plug P4. The thermal breaker is reset by pres
button at the center between its two terminals. Unplug the TV before pressing.

Shutdown - Temperature LED blinks continously

Refer to figure 39. If the temperature LED blinks continously, the TV is either too hot or
the temperture sensor (IC6904) is defective. The eight pin DIP package (IC6904) is
connected to the microprocessor on the IIC bus. If the bus between this IC and the
microprocessor is broken, the TV will not shut down. Therefore if a shutdow
occur because of IC6904, check for air blockage about the color wheel housing,
unstable supply voltage (3.3V) before replacing the IC. Do not disconnect IC6904.
H
igh temperatures will damage the expensive L board.
IIC data / clock
Color
wheel
assembl
Figure 38 - Powe
3.3V
Temp
Sensor
Figure 39 - Temperature LED Blinks continuously
er an open lamp door switch or
r LED Blinks continuously
L
Bd.
data
4
4
4
4
5
5
5
5
clock
L5 / DG15
CW1 / L2
42
sing the
n does
DG Bd.
Micro
IC1103