Defective Lamp Symptoms, Replacement, & Time Reset; Lamp End Of Life Symptoms - Panasonic PT-50DL54 Technical Manual

High definition dlp projection television
Hide thumbs Also See for PT-50DL54:
Table of Contents

Advertisement

Defective Lamp Symptoms, Replacement, & Time Reset

Lamp End of Life Symptoms

Two symptoms can occur requiring lamp replacement:
Symptom
1. The front panel Lamp LED
blinks (red) without pause.
The Power LED blinks orange.
2. Picture blinks or TV works for
5-20mins then goes dark, re-
lighting in about 40 sec.
Notice
– Before replacing the lamp, verify the ballast circuitry operation. Remove the
lamp and then replace the lamp door (without a lamp inside). Remove the rear panel
(18 screws). Refer to figure 24 for the location of spark gap Z001. While watching
spark gap Z001 through the perforated ballast shield, turn-on the TV. After 38 seconds,
the spark gap should emit light caused by a HV arc, which should last for about 1/2
second. The presence of the arc indicates that the ballast is working properly and that
the defect must be in either the lamp or in its socket. If no arc is evident, check for 2 DC
voltages input the ballast board before replacing the ballast (see ballast section for
diagrams). The shield was removed in figure 25 to help in locating Z001 only. Do not
remove the shield.
Lamp Failure Symptoms
Problem
Lamp is cracked or not
drawing current (defective)
or the ballast is bad. See
notice below.
Lamp is at end of life.
Table 12
Figure 24 - TV rear view (bottom)
31
Remedy
Test the ballast (see notice).
Replace the lamp if the ballast is
OK and reset the lamp time
(lamp time reset).
Replace the lamp
(part # TY-LA2004).
Reset the lamp time.
Z 001
See figure 25

Advertisement