Wall-Mounting The Layered Storage Tank; Wall-Mounting The Boiler - Vaillant ecoTEC plus VUI Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

4
Installation
4.6

Wall-mounting the layered storage tank

Danger!
a
Risk of death if the load-bearing capacity
of the fixing elements used is insuffi-
cient!
If the fixing elements or wall do not have
sufficient load-bearing capacity, the layered
storage tank may come loose and fall down.
This may also cause leaks in the gas line,
which is potentially fatal.
> When installing the layered storage tank,
ensure that the fixing elements and the
wall have a sufficient load-bearing capac-
ity.
> Check the quality of the wall.
1
2
3
4.5 Wall-mounting the layered storage tank
> Mount the hanging bracket (1) on the wall using the rawl
plugs and screws (2) provided with the unit.
> Hang the layered storage tank (3) on the suspension
bracket from above using the hanging bracket.
20
4.7

Wall-mounting the boiler

1
4.6 Wall-mounting the boiler
> Lift the VUW boiler (2) onto the layered storage tank so
that it is slightly above the hanging bracket on the lay-
ered storage tank (1).
i
Raise the VUW boiler on both sides of the floor.
> Slowly lower the VUW boiler onto the hanging bracket on
the layered storage tank so that the suspension bracket
on the rear side of the VUW boiler completely engages
into the hanging bracket on the layered storage tank.
Installation and maintenance instructions ecoTEC plus 0020134833_01
2

Advertisement

Table of Contents
loading

Table of Contents