Using The Mounting Template; Wall-Mounting The Product - Vaillant ecoFIT sustain Series Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

6.6.3
Flue Configuration Description
6.6.3.1 Horizontal Concentric Flue ⌀ 60/100 mm or
⌀ 80/125 mm (C13 type installation)
1
1
Gasket (fitted)
Note
If the terminal is at less than 1.80 m from the
ground, you must install a terminal protection kit.
Consult the separate installation manual for air/flue gas sys-
tems supplied with your appliance for all possibilities and as-
sociated accessories and how to install the flue system.
6.6.3.2 Terminal protection
A terminal guard is required if persons could come into con-
tact with the terminal or the terminal could be subject to dam-
age.
If a terminal guard is required, it must be positioned to
provide minimum of 50 mm clearance from any part of the
terminal and be central over the terminal.
The guard should be similar to that shown in the figure.
0020230529_06 ecoFIT sustain Installation and maintenance instructions
6.6.3.3 Vertical Concentric Flue ⌀ 60/100 mm or
⌀ 80/125 mm (C33 type installation)
Consult the separate installation manual for air/flue gas sys-
tems supplied with your appliance for all possibilities and as-
sociated accessories and how to install the flue system.
6.7

Using the mounting template

Use the mounting template to ascertain the locations at
which you need to drill holes.
6.8

Wall-mounting the product

Note
If you are using the rear air/flue connection, in-
stall the air/flue pipe before you wall-mount the
product.
1.
Check the load-bearing capacity of the wall.
2.
Note the total weight of the product.
3.
Only use fixing material that is permitted for the wall.
4.
If required, ensure that mounting apparatus on-site has
sufficient load-bearing capacity.
5.
Wall-mount the product as described.
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents