Summary of Contents for Vaillant ecoTEC plus Series
Page 1
For the owner Instructions for use ecoTEC Wall hung room sealed fan assisted condensing boilers Supplied By www.heating spares.co Tel. 0161 620 6677...
1 Notes on these instructions Specified use Specified use ..............2 Notes on these instructions ......2 The Vaillant ecoTEC plus, ecoTEC pro and ecoTEC exclusive Storage of the documents ........models are compact, wall-mounted condensing boilers. Symbols used in this manual .........
Danger Data badge Inflammable mixtures of gas and air may The type plate of the Vaillant ecoTEC is attached at the explode. Do not use or store explosive or easily factory to the bottom of the appliance. flammable substances such as petrol or paint in the same room as the appliance.
Page 4
2 Safety Caution Note Inappropriate modifications can cause damage. It cannot be guaranteed that water will circu- Never tamper with the boiler or other parts of late throughout the entire heating system. the system. Never attempt to perform maintenance or re- If the boiler is not operated for several hours during pairs yourself.
The cost of this annual service is not included in the 3.4.1 The appliance guarantee. Do not dispose of your Vaillant ecoTEC boiler or any of its accessories with household waste. Make sure the 3.1.2 One year guarantee for ecoTEC pro boilers...
4 Operation Operation shows the current heating flow temperature (in this ex- ample 45 °C). In the event of a fault, an error code ap- Overview of controls on ecoTEC plus and pears instead of the temperature. The ecoTEC exclusive ecoTEC exclusive display has also cleartext for a direct information The display also gives the following information:...
Operation 4 Flame with cross: Boiler is at lock out and will display fault code Flame without cross: Normal burner operation Overview of controls on ecoTEC pro Fig. 4.4 ecoTEC pro indicator lights Display indicating flow temperature or the system pressure or the relevent fault code.
4 Operation The flow, return and gas service valves are open when the line marking has the same direction as the pipe. Attention The pressure relief valve is provided for safety reasons and must not be interfered with. Note A bottom cover is fitted to the appliance. The service valves are fitted behind this cover.
Operation 4 Note Your appliance has a pressure sensor. plus/exclusive If the pressure falls below 0.6 bar the pressure flashes in the display. If it falls below 0.3 bar the appliance switches off. The error message F.22 appears in the dis- play.
4 Operation Fig. 4.12 Drawing off hot water (example: ecoTEC plus) Heating operation The boiler must only be used when the heating system Fig. 4.10 Switching the warmstart system on and off with contains water (see 4.3.2). ecoTEC plus and ecoTEC exclusive ecoTEC pro 4.6.1 Setting the maximum radiator temperature control...
S.14 Burner ignited Displays for hot holding operation Note (ecoTEC combination boilers only) Vaillant offer room thermostat/time control ac- S.20 Hot holding request cessories which give accurate and economic room S.24 Hot burner holding operation on temperature control as well as improved comfort.
Inappropriate modifications can cause damage. help to pinpoint the fault. If your boiler still does not operate then please consult your installer or Vaillant Service Solu- Turning off the boiler tions (0870 6060 777). 4.8.1 Problems due to low system water pressure The device switches to “Fault”...
Inspection and maintenance Permanent operational readiness, reliability and a long service life require inspections and maintenance work to be regularly carried out by a heating engineer or Vaillant. For further details please contact Vaillant Service Solu- tions: (0870 6060777). Instructions for use ecoTEC / 838402_06...
Page 14
Supplied By www.heating spares.co Tel. 0161 620 6677...
Page 15
Supplied By www.heating spares.co Tel. 0161 620 6677...
Page 16
Supplied By www.heating spares.co Tel. 0161 620 6677...