Adapting the boiler to the heating installation
Code
Parameters
D.090
Status of digital controller
D.091
Status DCF with external sensor con-
nected
D.092
actoSTOR module recognition
D.093
Setting of device specific number (DSN) Setting range: 0 to 99
D.094
Delete fault history
D.095
Software version of PeBUS components
D.096
Factory setting
D.098
Value of coding resistors for gas group
and output range
11.1 Diagnostics codes (continued)
11.1.1

Setting the heating partial load

The heating partial load of the Vaillant ecoTEC plus boiler is
factory set to "auto". This means that the boiler automati-
cally determines the optimum heating output depending on
the current heat demand of the system. A setting is nor-
mally no longer required. If you still want to set a fixed
maximum heating partial load, you can set a value under
diagnostics code "D.000" which equates to the boiler out-
put in kW.
11.1.2
Setting pump overrun time and pump
operating mode
The pump overrun time for the heating mode is set at the
factory to a value of 5 minutes. You can set the pump over-
run time under diagnostics code "D.001" within the range of
1 minute to 60 minutes. You can set a different pump oper-
ating mode under diagnostics code "D.018". Here you have
the choice between Eco and Comfort.
54
Adjustable values
recognised, not recognised
No reception
Reception
Synchronised
Valid
- Not connected
- Connection error: No communication via PeBus, acto-
STOR module detected previously
- Connection active
Delete fault list
PCB (BMU)
Display(AI)
actoSTOR(APC)
HBI/VR34
Reset all adjustable parameters to default setting
Display xx.yy
xx = Coding resistor 1 in cable harness for output
range:
11 = VUI 937
yy = Coding resistor 2 on PCB for gas group:
02 = P-Gas
03 = H Gas
Comfort (continuously operating pump)
The internal pump is switched on when the heating flow
temperature is not at "Heating off"(¬ Operating instruc-
tions) and the heating requirement is enabled via an exter-
nal controller.
Installation and maintenance instructions ecoTEC plus 0020134833_01
Factory set-
Your own
ting
setting
Not adjustable
Not adjustable
Not adjustable
Not adjustable