10.2.4 Target feed temperature

Use the minus button and the plus button to set the target
feed temperature. Confirm your setting with OK.

10.2.5 Hot water temperature

Use the minus button and the plus button to set the hot
water temperature. Confirm your setting with OK.

10.2.6 Comfort mode

Use the minus button and the plus button to enable or disa-
ble comfort mode. Confirm your setting with OK.

10.2.7 Heating partial load

The heating partial load of the Vaillant ecoTEC plus boiler is
factory set to "auto". This means that the boiler independ-
ently determines the optimum heating output depending on
the current heat demand of the system. A setting is nor-
mally no longer required.
The setting can also be changed later using diagnostics
code D.000.
i
If you have activated the return flow tempera-
ture control under D.017, the automatic heating
output determination function is not active. If
you set D.000 to "auto" anyway, the boiler oper-
ates with the maximum possible heating partial
load.

10.2.8 Auxiliary relay and multi-functional module

Additional components that are attached to the boiler can
be adjusted directly here.
This setting can be changed using diagnostics codes D.026,
D.027 and D.028.

10.2.9 Competent person telephone number

You can store telephone numbers in the menu.
The operator can display these in the information menu.
The telephone numbers can be up to 16 digits long and
must not contain any spaces. If the telephone number is
shorter, end the entry after the last digit by pressing the
right-hand selection button.
All of the digits to the right will be deleted.
Installation and maintenance instructions ecoTEC plus 0020134833_01

10.2.10 Terminating the installation assistant

If you have successfully run through and confirmed the
installation assistant, it will not start up automatically next
time the unit is switched on.

10.2.11 Restarting the installation assistant

You can restart the installation assistant any time by calling
it up manually in the menu.
Menu ¬ Installer level ¬ Installation assistant
10.3
Appliance configuration and diagnostics
menu
If you have already filled and purged the heating installa-
tion and have terminated the installation assistant but wish
to set the most important system parameters again, you
can also call up the "Appliance configuration" menu point.
Menu ¬ Installer level ¬ Appliance configuration
All of the setting options for more complex systems can be
found in the diagnostics menu (¬ section 11).
Menu ¬ Installer level ¬ Diagnostics menu
10.4

Using test programs

As well as the installation assistants, you can also
call up the test programs for commissioning.
Menu ¬ Installer level ¬ Test programs
As well as the function menu (¬ section 12.3), an electron-
ics self test facility (¬ section 12.3.1) and the gas family
check (¬ section 12.1.5), you will also find the test programs
here.
Menu ¬ Installer level ¬ Test programs -> Test programs
If you activate different test programs, you can
trigger special functions on the boiler.
The following four test programs are available:
Commissioning