Thermostat Hi-Limit - Asko TLS752 Manual

Table of Contents

Advertisement

1. Function
• This is a bimetal-type switch which controls the heater operation.
• If the heater is too hot, this thermostat stops the heater and after the heater
is cooled down, it restarts the heater.
2. Specification
• A bimetal thermostat with the terminals normally connected
• Electric rating : 25A at 125V
• Opening temperature : 125±4°C, Closing temperature : 94±5.5°C
• Type name : 60T
3. Checking method of mal-function
• After 3 minutes of the air dry program, the terminals of this part are connected to each other.
• Press the power and start buttons while you push the door switch after opening the door.
• Check if the heater operates after the drum starts rotating.
(To do this, check if the heater turns red or feel warm air in the drum with your hands).
• If the heater operates, run the air dry program for more than 3 minutes after closing the door.
• Switch off the power and measure the resistance between the terminals. If the value is greater than 1,
replace the switch.
4. Procedure of replacement
① Remove the back cover.
② Check the position of the part
③ Remove the wires and screws to disassemble the part.
④ Assemble the parts in reverse order.

Thermostat Hi-Limit

Thermostat Control
Thermostat Control
52
Part Code : 3619047600

Advertisement