❏ Electric Parts List - Gas Clothes Dryer
Part Name
Part Code
Lamp AS
3612625300
Switch Door
3619047700
Thermistor
361AAAAC20 CWT-DEW-1C18-A
Fan
Switch Micro
3619047500
Unit Steam AS
3619606700
Motor Dryer
36189L5D00
Igniter AS
36189L5800
Flame Sensor
3614825700
Thermostat
3619047610
Hi-Limit
Thermostat
3619047810
Cut-Out
Valve Gas AS
3615417200
Valve Gas AS
3615417300
* Parts surrounded by dotted line are exclusively for gas dryer. Other parts are common parts for electric/ gas dryer.
Type No
Lamp Holder: 4000
series
Lamp Base: E12
SPE110F-1D3
GSM-V1622A2
MSS13
S58NXSDD-6989
DC033
10RS 43828
60T21
PBR-380 N110
"DEGB-1011, LPG"
"DEGB-1011, LNG"
Rating
75W, 125V
15W, 125V
7.5A 125V / 5A 250V AC
5V R40=26.065KΩ
R90=4.4278KΩ
125V/250V 16A N-C
120V 60Hz 1300W
120V 60Hz 5.9A CL.B
120V 60Hz 4.0A
120V 60Hz 5.75A
95°C Off, 70°C On
125V/25A 250V/25A
110°C Off, -35°C On
125V/15A 250V/7.5A
2.0~3.5 kPa, 120V 0.07A
1.0~3.5 kPa, 120V 0.07A
49
Main function
Power is applied to the lamp to turn
up the light in the drum when the
door is opened.
Themistor fan senses the
temperature of exhaust air and turns
on/off the heater if the temperature
is higher/lower than the set temp.
Switch micro detects a loosened or
broken belt so as to block power to
the motor.
The followings are the main
advantages of STEAM UNIT
AS: Wrinkle remover, static-free,
protection against odour in clothes.
The motor rotates the drum to dry
laundry evenly and the fan to expel
wet air.
When power is supplied, igniter is
heated to 980°C (1800 °F) within 30
seconds to ignite gas.
When heat source is detected,
contact point is opened within 12 ~
20 seconds to turn off igniter before
gas ignition. When heat source is
extinguished, contact point is closed
within 26 ~ 40 seconds.
To prevent overheating around
burner during normal operation,
power line of flame sensor is cut
off when the temperature detected
reaches 95°C and is restored when
the temperature falls below 70°C.
Overheating around burner
is prevented under abnormal
conditions, such as of lint filter or
exhaust pipe blocking (manual
restoration possible by pressing
knob after operation commences).
LPG gas is supplied or blocked off.
LNG gas is supplied or blocked off.

Advertisement