Asko TLS752 Manual page 30

Table of Contents

Advertisement

4) Temp Control
A. If you press this button, the following is displayed in order.
Medium - Mid High - High - Ultra Low - Low - Medium
B. Each level targets temperatures as follows. (Target temperatures : Thermostat fan)
Level
High
Mid High
Medium
Low
Ultra Low
C. This is available only in Manual Dry Course not Sensor Dry Course.
5) Time Dry
A. If you press this button, the following is displayed in order.
40 - 50 - 60 - 20 - 30 - 40
B. Pushing More Time or Less Time button increases or decreases time by a minute. The maximum drying time
is 1 hour and 50 minutes and minimum 10 minutes (the indicated time includes 5 minutes of cooling).
C. If you select Time Dry, Dry Level and Course LED go off. That is, you can not choose Dry Level and Course
but only temperatures (default is High).
D. 5 levels of temperatures are available.
6) Beeper
A. If you press this button, the following is displayed in order.
'High -  - Low -  - Off'
B. Then, the volume of the beeper changes.
C. You can not change the beeper while the unit is in operation or stops temporarily.
7) More Time
A. Pressing this button increases time by a minute.
B. The time increases up to 1:55 (minutes)
C. You can change time in Manual Dry Course and Time Selection. Also Wrinkle Care can be selected/
cancelled.
Target Temperatures
Heater-Off(°C)
63
59
55
50
46
30
Heater-On(°C)
58
54
50
45
41