Sidewall clearances: The clearance from the inside of the
firebox to perpendicular combustible side wall should not
be less than 6". See Figure 1.
Firebox Side and Back clearances: The firebox outer
casing side and back flanges are zero clearance to
combustibles.
Top Framing and Finishing: Combustible framing may rest
on top of standoffs. Combustible finishing materials may
extend to the top standoff screws on the front edge of the
outer wrap. See Figures 2a & 2b.
FRONT FACE (SIDE)
WITH ACCESSORY LINER ONLY
with Accessory Liner Only
Page 4

CLEARANCES

COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
FIREBOX
(TOP VIEW)
3"
MAX.
45°
6"
PERPENDICULAR
SIDE WALL
Figure 1
2 X 4
HEADER
STAND OFF
FIREBOX
Figure 2a - Louvered Models
2 X 4
HEADER
TOP OUTER
WRAP
STAND OFF
FIREBOX
Figure 2b - Flush Models
COMBUSTIBLE
FINISHED WALL
OR MANTEL
FINISH WITH TRIM KIT OR
NON-COMBUSTIBLE MATERIAL
AS DESIRED.
COMBUSTIBLE
FINISHED WALL
OR MANTEL
FINISH WITH TRIM KIT
OR NON-COMBUSTIBLE
MATERIAL AS DESIRED.