Empire Comfort Systems vfp36pp32EN-2vfp36pp32Ep-2 Installation Instructions And Owner's Manual

Empire Comfort Systems vfp36pp32EN-2vfp36pp32Ep-2 Installation Instructions And Owner's Manual

Premium vent-free multi-sided fireplaces

Advertisement

Quick Links

EMPIRE
EMPIRE
Comfort Systems
Premium Vent-Free
Multi-Sided Fireplaces
ANSI Z21.11.2 Gas Fired Decorative Type Unvented
Room heaters.
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNINg: If the information in these instructions
are not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WhAT TO DO If yOU SMELL gAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
SEE-ThROUgh fIREpLACE MODELS:
vfp36Sp32EN-2
vfp36Sp32Ep-2
pENINSULA fIREpLACE MODELS:
vfp36pp32EN-2
vfp36pp32Ep-2
GAS-FIRED
U.L. fILE: Mh46389
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
This is an unvented gas-fired heater. It uses air (oxy-
gen) from the room in which it is installed. provisions
for adequate combustion and ventilation air must be
provided. Refer to page 8.
WARNINg: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
WATER vApOR: A By-pRODUCT Of UNvENTED ROOM
hEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU's (.3KW's)
of gas input per hour. Refer to page 8.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems vfp36pp32EN-2vfp36pp32Ep-2

  • Page 1 INSTALLATION INSTRUCTIONS EMPIRE EMPIRE AND OWNER'S MANUAL Comfort Systems Premium Vent-Free SEE-ThROUgh fIREpLACE MODELS: vfp36Sp32EN-2 Multi-Sided Fireplaces vfp36Sp32Ep-2 pENINSULA fIREpLACE MODELS: vfp36pp32EN-2 vfp36pp32Ep-2 GAS-FIRED U.L. fILE: Mh46389 ANSI Z21.11.2 Gas Fired Decorative Type Unvented Room heaters. Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
  • Page 2: Table Of Contents

    TABLE Of CONTENTS SECTION pAgE Carton Contents .......................3 Hardware Package ....................3 Important Safety Information ..................4 Safety Information for Users of LP-Gas ..............5 Introduction ......................6 Specifications ......................7 Water Vapor: A By-Product of Unvented Room Heaters ..........8 Provisions for Adequate Combustion & Ventilation Air ..........8-9 Gas Supply ......................10 Clearances ......................11-12 Combustible Materials ....................12...
  • Page 3: Carton Contents

    CARTON CONTENTS Fireplace Assembly Lava Rock Package Soot Warning Sheet Installation package Rockwool Packet Installation Instructions Serial Number Tag Warranty Card Hardware Package (See Figure Below) Nailing Flange #10 x 1/2" Phillips Hex Head Screw #10 x 1/2" Phillips Truss Head Screw Romex Connector HARDWARE PACKAGE #10 X ½”...
  • Page 4: Important Safety Information

    IMpORTANT SAfETy INfORMATION components of this appliance are treated with certain oils, DANgER: Indicates a hazardous situation which, if not avoid- films or bonding agents. These bonding agents are not ed, will result in death or serious injury. harmful but may produce annoying smoke and smells as they are burned off during initial operation of the appliance.
  • Page 5: Safety Information For Users Of Lp-Gas

    SAfETy INfORMATION fOR USERS Of Lp-gAS Propane (LP-Gas) is a flammable gas which can cause fires point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone's safety will depend colorless.
  • Page 6: Introduction

    INTRODUCTION Instructions to Installer Installation on Rugs and Tile 1. Installer must leave instruction manual with owner after If this appliance is installed directly on carpeting, tile or other installation. combustible material other than wood flooring the appliance shall 2. Installer must have owner fill out and mail warranty card supplied be installed on a metal or wood panel extending the full width and with unvented room heater.
  • Page 7: Specifications

    SpECIfICATIONS Model VFP36(SP,PP)32EN (NAT) VFP36(SP,PP)32EP (LP) Input Maximum 38,000 38,000 Minimum 25,000 30,000 Overall Dimensions Height without standoff 37 3/4" 37 3/4" Width 39" 39" Depth 24" 24" Gas Inlet 3/8" 3/8" Log Sets (ordered Separately) LSU24RR-2 Accessories EK-1 Embers Kit Embers Kit PE-20 Platinum Embers...
  • Page 8: Water Vapor: A By-Product Of Unvented Room Heaters

    WATER vApOR: A By-pRODUCT Of UNvENTED ROOM hEATERS Water vapor is a by-product of gas combustion. An unvented room The following steps will help insure that water vapor does not heater produces approximately one (1) ounce (30ml) of water for become a problem.
  • Page 9: Provisions For Adequate Combustion & Ventilation Air

    pROvISIONS fOR ADEqUATE COMBUSTION & vENTILATION AIR (continued) The space in the above example is a confined space because the Ventilation Air From outdoors (Figure 2) actual BTU/Hr used is more than the maximum BTU/HR the space Provide extra fresh air by using ventilation grills or ducts. You must can support.
  • Page 10: Gas Supply

    gAS SUppLy Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended gas pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 feet 1/2”...
  • Page 11: Clearances

    CLEARANCES Combustible material clearance from front of firebox: 36" Sidewall Clearances: The clearance from the inside of the fireplace minimum to perpendicular combustible side wall should not be less than 1 3/4". See figures 4a and 4b. fireplace Side and Back Clearances: The fireplace outer casing side(s) require a minimum 1/2"...
  • Page 12: Combustible Materials

    CLEARANCES (cont.) Ceiling Clearances: The ceiling height should not be less than 42" the clearance requirements detailed below. from the top of the hood. See figures 6a and 6b. Leave furniture and other combustible items at least 36" away from Mantel Clearances: Vent free fireplace models must use the hood the front openings of the fireplace.
  • Page 13: Planning Installation

    pLANNINg INSTALLATION If the fireplace is installed directly on carpeting, tile or other In planning the installation for the fireplace, it is necessary to combustible material other than wood flooring, it should be installed determine where the unit is to be installed and whether optional on a metal or wood panel extending the full width and depth of the accessories are desired.
  • Page 14 FIREPLACE INSTALLATIoN INSTRUCTIoNS (continued) 2 9/16” 2 9/16” 2 9/16” SEE THRU PENINSULA LOUVERED LOUVERED vfp36Sp vfp36pp 34 3/4" 34 3/4" 39" 39" 24" 24" 22" 22" 36" 36" 34 1/4" 35 1/4" 29 1/8" 29 1/8" 37 3/4" 37 3/4" 1 1/4"...
  • Page 15 FIREPLACE INSTALLATIoN INSTRUCTIoNS (continued) Locating fireplace Place fireplace in framed opening. Attach the framing brackets to the fireplace and secure to framing. Different hole locations can be used for finishing materials with thicknesses of 3/8", 1/2" and 3/4". Secure the brackets with screws provided using two (2) per framing bracket.
  • Page 16: Installing Hoods

    INSTALLINg hOODS Black hoods are furnished with each fireplace (or the optional Extended hoods hood(s)) and MUST be installed before the fireplace is used. Failure If your non-combustible facing material is over 1" in thickness and to do so may create a possible fire hazard. For shipping purposes, will be used to finish this fireplace, extended hoods are available the hoods are located behind the upper or lower louvers.
  • Page 17: Gas Line Connection

    gAS LINE CONNECTION The fireplace is designed to accept a gas line for connection to the gas valve. Have the line installed by a qualified service person in accordance with all building codes. Consult local building codes to properly size the gas supply line leading to the connection of the valve.
  • Page 18: Placement Of Glowing Embers And Lava Rock

    PLACEMENT oF GLoWING EMBERS AND LAVA RoCK Placement of the glowing embers (rockwool) is very individual and placing Lava Rock in front of Burner on fireplace floor light coverage of the areas indicated will provide your best effects. Spread lava rocks on fireplace floor in front of the burner pan. The We recommend separation of the rockwool by hand and to make lava rocks are for decorative effect and are not required for fireplace your coverage as light and fluffy as possible.
  • Page 19: Operation Instructions/Flame Appearance

    oPERATIoN INSTRUCTIoNS/FLAME APPEARANCE Before you begin: Do not handle the logs with your bare hands! appliance, possibly causing headaches or eye or lung irritation. This Always wear gloves to prevent skin irritation. After handling logs, is a normal and temporary occurrence. wash your hands gently with soap and water.
  • Page 20: Vfp36(Sp,Pp)32 Lighting Instructions

    MILLIvOLT vALvE LIghTINg INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNINg: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by department.
  • Page 21: Burner Instructions

    BURNER INSTRUCTIONS Check the following items during installation prior to lighting • When first lighting the pilot on the burner, it takes approximately the multisided burner: 60 to 75 seconds to fully heat and energize the thermopile. Once the thermopile is energized, turn on the gas valve and •...
  • Page 22: Pilot Flame Characteristics

    pILOT fLAME ChARACTERISTICS Figure 16 show a correct pilot flame pattern. The correct flame will Cleaning and pilot Maintenance be blue and will extend beyond the thermocouple. The flame will oxygen Depletion Sensor Pilot (Figure 18) surround the thermocouple just below the tip. A slight yellow flame When the pilot has a large yellow tip flame, clean the Oxygen may occur where the pilot flame and main burner flame meet.
  • Page 23: Wiring

    WIRINg Label all wires prior to disconnection when servicing controls. Wiring the gas valve. errors can cause improper and dangerous operation. Verify proper Attention: The remote receiver bracket is not used in this operation after servicing. installation. 1. The remote receiver can not be placed behind the gas valve Millivolt thermopile is self powered, gas valve does not require 110 and burner assembly.
  • Page 24: Troubleshooting Symptoms - Possible Causes And Solutions

    TROUBLEShOOTINg SyMpTOMS - pOSSIBLE CAUSES AND CORRECTIONS heater. Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the 7. oDS/pilot lights but flame goes out when control knob is 1. When ignitor button is pressed, there is no spark at oDS/ released.
  • Page 25: Wiring Instructions For Installing A Dual Switch/Receptacle

    WIRING INSTRUCTIoNS FoR INSTALLING A DUAL SWITCH / RECEPTACLE In order to install both the optional Blower and Accent Light acces- CAUTION sories, it will be necessary to install the junction box so that the Duplex Receptacle wiring is split. This will allow each side of the ALL WIRINg ShOULD BE DONE By A qUALIfIED ELECTRI- receptacle to operate independently off separate wall switches.
  • Page 26 oPTIoNAL FBB5 BLoWER INSTALLATIoN INSTRUCTIoNS To install the blower kit, access the junction box, or install a light Attention: Install blower assembly before connecting gas in- kit, remove lower louver as illustrated by figure 21. let supply line. A factory included junction box is located on the lower right side Wiring of the fireplace.
  • Page 27: Optional Blower Installation Instructions

    oPTIoNAL BLoWER INSTALLATIoN INSTRUCTIoNS (continued) NOTICE: This blower is equipped with a heat activated fan control Insert blower assembly into interior, bottom of firebox. switch. Blower will operate when the fireplace warms NOTICE: On peninsula models, the blower must be installed up, and will turn off automatically when the fireplace at the end which has the brick panel installed.
  • Page 28: Optional Blower Installation Instructions

    oPTIoNAL BLoWER INSTALLATIoN INSTRUCTIoNS (continued) Blower Motor Wiring The blower motor does not have oiling holes. Do not attempt to oil The appliance, when installed, must be electrically grounded in the blower motor. accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical Blower Wheels source is utilized.
  • Page 29: Lk2 Accent Light Accessory

    LK2 ACCENT LIGHT ACCESSoRY An Accent Light Kit model LK2 is available for installation in the top of the firebox. Providing the junction box has been pre-wired with separate circuits as described in the "Wiring for a dual switch/receptacle" section. Follow the instructions provided with the LK2 Accent Light kit for proper installation in the fireplace.
  • Page 30: Parts List

    pARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. pART NUMBER INDEX DESCRIpTION NUMBER vfp36Sp32EN vfp36Sp32Ep vfp36pp32EN vfp36pp32Ep 17301 17301 17301 17301 TOP STANDOFF R3491 R3491 R3491 R3491 COVER, JUNCTION BOX R3492 R3492 R3492...
  • Page 31 pARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. pART NUMBER INDEX DESCRIpTION NUMBER vfp36Sp32EN vfp36Sp32Ep vfp36pp32EN vfp36pp32Ep 23244 23244 23244 23244 VENTURI SHIELD R10947 R10947 R10947 R10947 WIRE ASSEMBLY R3436 R3436 R3436 R3436...
  • Page 32: See-Through Fireplace Parts View

    SEE-ThROUgh fIREpLACE pARTS vIEW 17 18 19 22 NAT. BURNER N a t G 36 37 Page 32 26670-4-0313...
  • Page 33: Peninsula Fireplace Parts View

    pENINSULA fIREpLACE pARTS vIEW 17 18 19 22 LP BURNER NAT. BURNER N a t G 36 37 26670-4-0313 Page 33...
  • Page 34: Accessories

    ACCESSORIES Accessory Description Model Numbers Fan Kit Designed to provide forced air flow. FBB5 Variable Speed Control Kit Wall mounted variable speed control for use SCV-1 with FBB5 blower Frame Kits Standard 3-Piece Frame Kits Black, Brass, Stainless Steel, or Hammered Pewter For use with See-Through mod- els: VFP36SP32 SERIES ONLY...
  • Page 35 ACCESSoRIES (continued) Accessory Description Model Numbers Accent Light Kit Optional light kit that installs in top of firebox to en- hance logset. Operates with a Rheostat control to vary brightness of light for desired effect. Extended hoods that extend out 2" farther than the Extended 4"...
  • Page 36: Master Parts Distributor List

    This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort. com. Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Dey Distributing East Coast Energy products...
  • Page 37: Reference

    Web Site: www.empirecomfort.com Empire Comfort Systems EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems Premium Vent-Free Fireplaces GAS-FIRED SEE-ThROUgh fIREpLACE MODELS: VFP36SP32EN-2 VFP36SP32EP-2 pENINSULA fIREpLACE MODELS: VFP36PP32EN-2 VFP36PP32EP-2 36-inch fireplace accommodates the following Log Set: Refractory Log Set: LSU-24RR-2 Banded Brick Liners are made from Ceramic Fiber for rich detail and lasting beauty.
  • Page 38 Web Site: www.empirecomfort.com Empire Comfort Systems EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems Premium Vent-Free Fireplaces SEE-ThROUgh fIREpLACE MODELS: pENINSULA fIREpLACE MODELS: VFP36SP32EN-2 VFP36PP32EN-2 VFP36SP32EP-2 VFP36PP32EP-2 Clearances Combustible material clearance (furniture, parallel walls) from front of fireplace: 36" minimum Sidewall Clearances: The clearance from the inside opening of the firebox to perpendicular combustible side wall should not be less than 1 3/4".
  • Page 39 Web Site: www.empirecomfort.com Empire Comfort Systems EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems Premium Vent-Free Fireplaces SEE-ThROUgh fIREpLACE MODELS: pENINSULA fIREpLACE MODELS: VFP36SP32EN-2 VFP36PP32EN-2 VFP36SP32EP-2 VFP36PP32EP-2 Clearances (continued) framing 1 3/4” MIN. 42” PERPENDICULAR MIN. COMBUSTIBLE (CEILING TO...
  • Page 40 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...

This manual is also suitable for:

Vfp36sp32en-2Vfp36sp32ep-2Vfp36pp32en-2Vfp36pp32ep-2

Table of Contents