Empire Comfort Systems VFP32BP series Owner's Manual

Empire Comfort Systems VFP32BP series Owner's Manual

Unvented gas fireplace

Advertisement

EMPIRE
EMPIRE
Comfort Systems
Vent-Free Gas Fireplaces
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explo-
sion may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
UNVENTED
GAS FIREpLACE
MODELS
VFp32Bp(20,21)L(N,p)-1
VFp32Bp(30,31)L(N,p)-1
VFp36Bp(20,21)L(N,p)-1
VFp36Bp(30,31)L(N,p)-1
This appliance may be installed in an aftermar-
ket, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to page 7.
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
WATER VApOR: A BY-pRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion.
An unvented room heater produces approximately
one (1) ounce (30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to page 7.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems VFP32BP series

  • Page 1 INSTALLATION INSTRUCTIONS EMPIRE EMPIRE AND OWNER'S MANUAL Comfort Systems Vent-Free Gas Fireplaces UNVENTED GAS FIREpLACE MODELS VFp32Bp(20,21)L(N,p)-1 VFp32Bp(30,31)L(N,p)-1 VFp36Bp(20,21)L(N,p)-1 VFp36Bp(30,31)L(N,p)-1 This appliance may be installed in an aftermar- ket, permanently located, manufactured (mobile) Installer: Leave this manual with the appliance. home, where not prohibited by local codes. Consumer: Retain this manual for future reference. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not WARNING: If the information in these instruc- convertible for use with other gases. tions are not followed exactly, a fire or explo- sion may result causing property damage, personal injury or loss of life. This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ................... 3 Safety Information for Users of LP Gas ..............4 Introduction ......................5 Specifications ......................6 Water Vapor: A By-Product of Unvented Room Heaters ......... 7 Provisions for Adequate Combustion and Ventilation Air ........7 - 8 Gas Supply .......................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION • An unvented room heater having an input rating of • During manufacturing, fabricating and shipping, various more than 6,000 Btu per hour shall not be installed in a components of this appliance are treated with certain bathroom oils, films or bonding agents. These bonding agents are not harmful but may produce annoying smoke and • An unvented room heater having an input rating of more smells as they are burned off during initial operation of than 10,000 Btu per hour shall not be installed in a bedroom the appliance. This is a normal temporary occurrence. or bathroom. A window should be opened during the initial bake out •...
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone's safety will depend colorless. you may not know all the following safety precau- on knowing exactly what to do. If, after reading the following tions which can protect both you and your family from an information, you feel you still need more information, please accident. Read them carefully now, then review them point by contact your gas supplier. Lp-GAS WARNING ODOR If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. That's your signal to go into immediate action! • Do not operate electric switches, light matches, use your •...
  • Page 5: Introduction

    INTRODUCTION Instructions to Installer 1. Installer must leave instruction manual with owner after Installation on Rugs and Tile installation. If this appliance is installed directly on carpeting, tile or other 2. Installer must have owner fill out and mail warranty card combustible material other than wood flooring the appliance supplied with unvented room heater.
  • Page 6: Specifications

    SPECIFICATIONS Model VFP32BP VFP36BP Input Maximum 32,000 36,000 Minimum 22,000 25,000 Minimum Firebox Opening Height without standoff 32 3/4" 34 3/4" Width 34” 39” Depth 17 3/8" 17 3/8” Gas Inlet 3/8” 3/8” Accessories EK-1 Embers Kit PE-20 Platinum Embers FBB4* Variable Speed Automatic Blower VPP32A VFP32BP —...
  • Page 7: Water Vapor: A By-Product Of Unvented Room Heaters

    WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS become a problem. Water vapor is a by-product of gas combustion. An unvented room 1. Be sure the heater is sized properly for the application, including heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour.
  • Page 8: Provisions For Adequate Combustion And Ventilation Air

    PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR (continued) Ventilation Air From Outdoors (Figure 2) The space in the above example is a confined space because the Provide extra fresh air by using ventilation grills or ducts. You must actual BTU/Hr used is more than the maximum BTU/HR the space provide two permanent openings: one within 12"...
  • Page 9: Gas Supply

    GAS SUPPLY Check all local codes for requirements, especially for the size and The use of the following gas connectors is recommended: type of gas supply line required. — ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings Recommended Gas Pipe Diameter —...
  • Page 10: Clearances

    GAS SUPPLY (continued) Checking Manifold Pressure VFp(32,36)Bp(20,21)Lp (Propane gas) will have a manifold pressure VFp(32,36)Bp(30,31)LN (Natural gas) will have a manifold approximately 10.0"w.c. (2.49kPa) at the pressure regulator outlet pressure of approximately 3.5" w.c. (.871kPa) for maximum input or with the inlet pressure to the pressure regulator from a minimum 1.7"...
  • Page 11: Combustible Materials

    COMBUSTIBLE MATERIALS Do not attach combustible material to the mantel of your fireplace. No greeting cards, stockings or ornamentation of any type should be This is a fire hazard. placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles.
  • Page 12: Fireplace Dimensions

    FIREPLACE DIMENSIONS STANDOFF GAS LINE OPENING GAS LINE OPENING JUNCTION BOX ASSEMBLY Figure 8 VFp32Bp VFp36Bp 34" 39" 29" 34" 17 3/8" 17 3/8" 31" 36" 22 7/8" 24 7/8" 32 3/4" 34 3/4" 31 7/8" 34 3/8" 45 1/8" 48 5/8"...
  • Page 13: Installing Hood And Trim Kit

    INSTALLING HOOD AND TRIM KIT A black hood and trim kit is furnished with each model Finishing VFP(32,36)BP fireplace. The hood MUST be installed before the All joints (top, bottom and sides), where the wall or decorative facing fireplace is used. Failure to do so may create a possible fire hazard. material meets the fireplace surround must be completely sealed Attention: The hood is located behind top louver during shipment with a non-combustible material.
  • Page 14: Fireplace Framing And Installation

    FIREPLACE FRAMING AND INSTALLATION 1. Place fireplace in framing opening. Fireplace framing can be built before or after the fireplace is set in 2. Using the four (4) nailing flanges provided with the fireplace, place. Framing should be positioned to accommodate wall covering attach two (2) flanges on each side.
  • Page 15: Placement Of Glowing Embers And Lava Rock

    Rock wool should not be placed in the area of the pilot assembly. Replacement of loose material (glowing embers) must be purchased from Empire Comfort Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater. WARNING: All previously applied loose material must be removed prior to reapplication.
  • Page 16: Operation Instructions/Flame Appearance

    OPERATION INSTRUCTIONS/FLAME APPEARANCE PERIODIC CLEANING – Refer to parts diagram for location of Flames from the pilot (rear right back side of the pan burner) as items discussed below. well as the main flame should be visually checked as the log set • Do not use cleaning fluid to clean logs or any part of heater. is installed.
  • Page 17: For Your Safety Read Before Lighting

    VFp(32,36)Bp(30,31) LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the fire hand. When lighting the pilot, follow these instructions department. exactly. C. Use only your hand to push in or turn the gas control B. BEFORE LIGHTING smell all around the appliance area knob. Never use tools. If the knob will not push in or for gas. Be sure to smell next to the floor because some...
  • Page 18: Vfp(32,36)Bp(20,21)L Lighting Instructions

    VFp(32,36)Bp(20,21) LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the fire hand. When lighting the pilot, follow these instructions department. exactly. C. Use only your hand to push in or turn the gas control B. BEFORE LIGHTING smell all around the appliance area knob. Never use tools. If the knob will not push in or for gas. Be sure to smell next to the floor because some...
  • Page 19: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS Figures 13 and 15 show a correct pilot flame pattern. The correct VFp(32,36)Bp(20,21) pILOT flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet.
  • Page 20: Wiring

    Cleaning and Pilot Maintenance Oxygen Depletion Sensor Pilot (Figure 17) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows: 1. Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench.
  • Page 21: Troubleshooting

    TROUBLESHOOTING SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater. a. Control knob not fully pressed in - Press in control 1. When ignitor button is pressed, there is no spark at ODS/pilot.
  • Page 22: Parts List

    PARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. Index Part Number Part Number Part Number Part Number Number VFp32Bp(20,21) VFp32Bp(30,31) VFp36Bp(20,21) VFp36Bp(30,31) Description 17149 17149 17149 17149 TOP STANDOFF 20098 20098 20126 20126 FIREBOX ASSEMBLY 10554 10554 10554...
  • Page 23: Parts View

    PARTS VIEW HYDRAULIC BURNER ASSEMBLY MILLIVOLT BURNER ASSEMBLY 28191-3-0611 Page 23...
  • Page 24: Optional Variable Speed Blower Installation Instructions

    OPTIONAL VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS FBB4 Blower Installation Attention: Install blower assembly before connecting gas inlet supply line. Note: junction box on right side of fireplace must be pre- wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate the power supply to the furnace by a qualified electrician.
  • Page 25: Optional Variable Speed Blower Installation Instructions

    OPTIONAL VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS (continued) Wiring Blower Motor The appliance, when installed, must be electrically grounded in The blower motor does not have oiling holes. Do not attempt to oil the blower motor. accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external Blower Wheels electrical source is utilized.
  • Page 26: Junction Box Wiring Installation Instructions

    JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION: ALL WIRING SHOULD BE DONE BY A qUALIFIED ELECTRICIAN AND SHALL BE IN COMpLIANCE WITH ALL LOCAL, CITy AND STATE BUILDING CODES. BEFORE MAKING ThE ELECTRICAL CONNECTION, MAKE SURE ThAT MAIN POWER SUP- PLy IS DISCONNECTED. ThE APPLIANCE, WhEN INSTALLED, MUST BE ELECTRICALLy GROUNDED IN ACCORDANCE WITh LOCAL CODES OR, IN ThE ABSENCE OF LOCAL CODES, WITh ThE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION). A factory installed junction box is located on the lower right hand side of the fireplace. Wiring must be fed to the junction box and attached to the receptacle that is provided.
  • Page 27: Master Parts Distributor List

    This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort. com. Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Dey Distributing East Coast Energy Products...
  • Page 28 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...

Table of Contents