Empire Comfort Systems VFP36SP32E Installation Instructions And Owner's Manual

Empire Comfort Systems VFP36SP32E Installation Instructions And Owner's Manual

Premium vent-free multi-sided fireplaces

Advertisement

Quick Links

PENINSULA SHOWN
ANSI Z21.11.2 Gas Fired Decorative Type
Unvented Room Heaters.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
— Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
WARNING
MULTI-SIDED FIREPLACES
SEE-THROUGH
FIREPLACE MODELS:
GAS-FIRED
VFP36SP32EN-3
VFP36SP32EP-3
U.L. FILE:
If not installed, operated and maintained
MH46389
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
This is an unvented gas-fired heater. It uses
air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion
and ventilation air must be provided. Refer
to page 8.
WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combus-
tion. An unvented room heater produces ap-
proximately one (1) ounce (30ml) of water for
every 1,000 BTU's (.3KW's) of gas input per
hour. Refer to page 8.
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
PREMIUM VENT-FREE
FIREPLACE MODELS:
WARNING
PENINSULA
VFP36PP32EN-3
VFP36PP32EP-3

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems VFP36SP32E

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL PENINSULA SHOWN PREMIUM VENT-FREE MULTI-SIDED FIREPLACES SEE-THROUGH PENINSULA FIREPLACE MODELS: FIREPLACE MODELS: GAS-FIRED VFP36SP32EN-3 VFP36PP32EN-3 VFP36SP32EP-3 VFP36PP32EP-3 WARNING U.L. FILE: If not installed, operated and maintained MH46389 in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion ANSI Z21.11.2 Gas Fired Decorative Type which can cause death or serious illness.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Carton Contents ..........................3 Hardware Package ........................3 Important Safety Information ......................4 Safety Information for Users of Propane Gas ................5 Introduction ............................ 6 Specifications ..........................7 Water Vapor: A By-Product of Unvented Room Heaters ..............8 Provisions for Adequate Combustion &...
  • Page 3: Carton Contents

    CARTON CONTENTS Fireplace Assembly Lava Rock Package Soot Warning Sheet Installation Package Rockwool Packet Installation Instructions Serial Number Tag Warranty Card Hardware Package (See Figure Below) Nailing Flange #10 x 1/2" Phillips Hex Head Screw #10 x 1/2" Phillips Truss Head Screw Romex Connector HARDWARE PACKAGE #10 X ½”...
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION DANGER: Indicates a hazardous situation which, if not avoided, will • WARnInG! This fireplace needs fresh air for ventilation to result in death or serious injury. run properly. This fireplace has an oDS (oxygen depletion sensor) which will shut down the heater if adequate fresh air is WARNING: Indicates a hazardous situation which, if not avoided, not available.
  • Page 5: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and explo- members of your household. Someday when there may not sions. In its natural state, propane is odorless and colorless. be a minute to lose, everyone's safety will depend on knowing You may not know all the following safety precautions which exactly what to do.
  • Page 6: Introduction

    INTRODUCTION Instructions to Installer NOTICE: During initial firing of this unit, its paint will bake out, and 1. Installer must leave instruction manual with owner after smoke will occur. To prevent triggering of smoke alarms, ventilate installation. the room in which the unit is installed. 2.
  • Page 7: Specifications

    SPECIFICATIONS Model VFP36(SP,PP)32EN (Natural) VFP36(SP,PP)32EP (Propane) Input Maximum 38,000 38,000 Minimum 25,000 30,000 Overall Dimensions Height without standoff 37 3/4" 37 3/4" Width 39" 39" Depth 24" 24" Gas Inlet 3/8" 3/8" Log Sets (Ordered Separately) LSU24RR-2 Accessories EK-1 Embers Kit Embers Kit PE-20 Platinum Embers...
  • Page 8: Water Vapor: A By-Product Of Unvented Room Heaters

    WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room The following steps will help insure that water vapor does not heater produces approximately one (1) ounce (30ml) of water for become a problem.
  • Page 9 PROVISIONS FOR ADEqUATE COMBUSTION & VENTILATION AIR (CONT'D) The space in the above example is a confined space because the Ventilation Air From Outdoors - Figure 2 actual BTU/Hr used is more than the maximum BTU/HR the space Provide extra fresh air by using ventilation grills or ducts. You must can support.
  • Page 10: Gas Supply

    GAS SUPPLY Check all local codes for requirements, especially for the size and type of gas supply line required. RECOMMENDED GAS PIPE DIAMETER Schedule 40 Pipe Tubing, Type L Pipe Inside Diameter Outside Diameter Length Natural Propane Natural Propane 0-10 feet 1/2”...
  • Page 11: Clearances

    CLEARANCES Combustible material clearance from front of firebox: 36" Sidewall Clearances: The clearance from the inside of the fireplace minimum to perpendicular combustible side wall should not be less than 1 3/4". See Figures 4a and 4b. Fireplace Side and Back Clearances: The fireplace outer casing side(s) require a minimum 1/2"...
  • Page 12: Combustible Materials

    CLEARANCES (CONT'D) Ceiling Clearances: The ceiling height should not be less than 42" the clearance requirements detailed below. from the top of the hood. See Figures 6a and 6b. Leave furniture and other combustible items at least 36" away from Mantel Clearances: Vent free fireplace models must use the hood the front openings of the fireplace.
  • Page 13: Planning Installation

    PLANNING INSTALLATION If the fireplace is installed directly on carpeting, tile or other In planning the installation for the fireplace, it is necessary to combustible material other than wood flooring, it should be installed determine where the unit is to be installed and whether optional on a metal or wood panel extending the full width and depth of the accessories are desired.
  • Page 14 FIREPLACE INSTALLATION INSTRUCTIONS (CONT'D) 2 9/16” 2 9/16” 2 9/16” SEE THRU PENINSULA LOUVERED LOUVERED VFP36SP VFP36PP 34 3/4" 34 3/4" 39" 39" 24" 24" 22" 22" 36" 36" 34 1/4" 35 1/4" 29 1/8" 29 1/8" 37 3/4" 37 3/4" 1 1/4"...
  • Page 15 FIREPLACE INSTALLATION INSTRUCTIONS (CONT'D) Locating Fireplace Place fireplace in framed opening. Attach the framing brackets to the fireplace and secure to framing. Different hole locations can be used for finishing materials with thicknesses of 3/8", 1/2" and 3/4". Secure the brackets with screws provided using two (2) per framing bracket.
  • Page 16 INSTALLATION You must install certain components before the fireplace is FRAMING THE FIREPLACE permanently installed. These include the direct-vent system, gas Choose fireplace location. piping for the appliance and the electrical wiring. (If the optional Frame in fireplace with a header across the top. It is important blower is used.) to allow for finished face when setting the depth of the frame.
  • Page 17: Installing Hoods

    INSTALLING HOODS Black hoods are furnished with each fireplace (or the optional Extended Hoods hood(s)) and MUST be installed before the fireplace is used. Failure If your non-combustible facing material is over 1" in thickness and to do so may create a possible fire hazard. For shipping purposes, will be used to finish this fireplace, extended hoods are available the hoods are located behind the upper or lower louvers.
  • Page 18: Gas Line Connection

    GAS LINE CONNECTION The fireplace is designed to accept a gas line for connection to the gas valve. Have the line installed by a qualified service person in accordance with all building codes. Consult local building codes to properly size the gas supply line leading to the connection of the valve.
  • Page 19: Placement Of Glowing Embers And Lava Rock

    PLACEMENT OF GLOWING EMBERS AND LAVA ROCK Placing Lava Rock in Front of Burner on Fireplace Floor Placement of the glowing embers (rockwool) is very individual and light coverage of the areas indicated will provide your best effects. Spread lava rocks on fireplace floor in front of the burner pan. The We recommend separation of the rockwool by hand and to make lava rocks are for decorative effect and are not required for fireplace your coverage as light and fluffy as possible.
  • Page 20: Operation Instructions/Flame Appearance

    OPERATION INSTRUCTIONS/FLAME APPEARANCE Before you begin: Do not handle the logs with your bare hands! appliance, possibly causing headaches or eye or lung irritation. This Always wear gloves to prevent skin irritation. After handling logs, is a normal and temporary occurrence. wash your hands gently with soap and water.
  • Page 21: Vfp36(Sp,Pp)32 Lighting Instructions

    MILLIVOLT VALVE LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by C. Use only your hand to push in or turn the gas control hand.
  • Page 22: Burner Instructions

    BURNER INSTRUCTIONS Check the following items during installation prior to lighting • For best results when lighting the burner, have your adjustable the multisided burner: flame knob to the HI position, then adjust to a lower setting after the burner has ignited. •...
  • Page 23: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS Figure 20 show a correct pilot flame pattern. The correct flame will Cleaning and Pilot Maintenance be blue and will extend beyond the thermocouple. The flame will Oxygen Depletion Sensor Pilot - Figure 22 surround the thermocouple just below the tip. A slight yellow flame When the pilot has a large yellow tip flame, clean the Oxygen may occur where the pilot flame and main burner flame meet.
  • Page 24: Wiring

    WIRING Label all wires prior to disconnection when servicing controls. Wiring the gas valve. errors can cause improper and dangerous operation. Verify proper Attention: The remote receiver bracket is not used in this operation after servicing. installation. 1. The remote receiver can not be placed behind the gas valve Millivolt thermopile is self powered, gas valve does not require 110 and burner assembly.
  • Page 25: Troubleshooting Symptoms - Possible Causes And Solutions

    TROUBLESHOOTING SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS heater. Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the 7. oDS/pilot lights but flame goes out when control knob is 1. When ignitor button is pressed, there is no spark at ODS/ released.
  • Page 26: Wiring Instructions For Installing A Dual Switch/Receptacle

    WIRING INSTRUCTIONS FOR INSTALLING A DUAL SWITCH / RECEPTACLE In order to install both the optional Blower and Accent Light acces- CAUTION sories, it will be necessary to install the junction box so that the Duplex Receptacle wiring is split. This will allow each side of the All wiring should be done by a qualified electrician and receptacle to operate independently off separate wall switches.
  • Page 27 OPTIONAL FBB5 BLOWER INSTALLATION INSTRUCTIONS To install the blower kit, access the junction box, or install a light Attention: Install blower assembly before connecting gas in- kit, remove lower louver as illustrated by Figure 25. let supply line. A factory included junction box is located on the lower right side of the fireplace.
  • Page 28: Optional Blower Installation Instructions

    OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (CONT'D) Insert blower assembly into interior, bottom of firebox. NOTICE: This blower is equipped with a heat activated fan control NOTICE: On peninsula models, the blower must be installed switch. Blower will operate when the fireplace warms up, and will at the end which has the brick panel installed.
  • Page 29 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (CONT'D) Blower Motor Wiring The blower motor does not have oiling holes. Do not attempt to oil The appliance, when installed, must be electrically grounded in the blower motor. accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical Blower Wheels source is utilized.
  • Page 30: Lk2 Accent Light Accessory

    LK2 ACCENT LIGHT ACCESSORY An Accent Light Kit model LK2 is available for installation in the top of the firebox. Providing the junction box has been pre-wired with separate circuits as described in the "Wiring for a dual switch/receptacle" section. Follow the instructions provided with the LK2 Accent Light kit for proper installation in the fireplace.
  • Page 31 This page intentionally left blank. 39813-1-0919 Page 31...
  • Page 32: Parts List

    PARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. PART NUMBER INDEX DESCRIPTION VFP36SP32EN VFP36SP32EP VFP36PP32EN VFP36PP32EP FIREBOX ASSEMBLY 17301 (4) 17301 (4) 17301 (4) 17301 (4) TOP STANDOFF R3491 R3491 R3491 R3491 JUNCTION BOX COVER...
  • Page 33 PARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. PART NUMBER INDEX DESCRIPTION VFP36SP32EN VFP36SP32EP VFP36PP32EN VFP36PP32EP R7591 R7591 R7591 R7591 FLEXLINE 15999 15999 15999 15999 ROCKWOOL BAG 24675 24675 BRACKET, LOG SUPPORT (REAR) 24676 24676 BRACKET, LOG SUPPORT (FRONT)
  • Page 34: See-Through Fireplace Parts View

    SEE-THROUGH FIREPLACE PARTS VIEW 17 18 19 22 NAT. BURNER N a t G 36 37 Page 34 39813-1-0919...
  • Page 35: Peninsula Fireplace Parts View

    PENINSULA FIREPLACE PARTS VIEW 17 18 19 22 LP BURNER NAT. BURNER N a t G 36 37 39813-1-0919 Page 35...
  • Page 36: Accessories

    ACCESSORIES Accessory Description Model Numbers Fan Kit Designed to provide forced air flow. FBB5 Variable Speed Control Kit Wall mounted variable speed control SCV-1 for use with FBB5 blower Frame Kits For use with See-Through models: VFP36SP32 SERIES Standard 3-Piece Frame Kits ONLY in Black or Hammered Pewter.
  • Page 37 ACCESSORIES (CONT'D) Accessory Description Model Numbers Accent Light Kit Optional light kit that installs in top of firebox to en- hance logset. Operates with a Rheostat control to vary brightness of light for desired effect. R9645 - REPLACEMENT BULB - (25W , 300°C, 125-130 VAC) Extended 4" Hoods Extended hoods that extend out 2"...
  • Page 38: Master Parts Distributor List

    This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com. Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Dey Distributing...
  • Page 39: Reference

    Web Site: www.empirecomfort.com Empire Comfort Systems EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems Premium Vent-Free Fireplaces GAS-FIRED SEE-THROUGH FIREPLACE MODELS: VFP36SP32EN VFP36SP32EP PENINSULA FIREPLACE MODELS: VFP36PP32EN VFP36PP32EP 36-inch Fireplace accommodates the following Log Set: Refractory Log Set: LSU-24RR-2 Banded Brick Liners are made from Ceramic Fiber for rich detail and lasting beauty.
  • Page 40 Web Site: www.empirecomfort.com Empire Comfort Systems EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems Premium Vent-Free Fireplaces SEE-THROUGH FIREPLACE MODELS: PENINSULA FIREPLACE MODELS: VFP36SP32EN VFP36PP32EN VFP36SP32EP VFP36PP32EP Clearances Combustible material clearance (furniture, parallel walls) from front of fireplace: 36" minimum Sidewall Clearances: The clearance from the inside opening of the firebox to perpendicular combustible side wall should not be less than 1 3/4".
  • Page 41 Web Site: www.empirecomfort.com Empire Comfort Systems EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems Premium Vent-Free Fireplaces SEE-THROUGH FIREPLACE MODELS: PENINSULA FIREPLACE MODELS: VFP36SP32EN VFP36PP32EN VFP36SP32EP VFP36PP32EP Clearances (continued) Framing 1 3/4” MIN. 42” PERPENDICULAR MIN. COMBUSTIBLE (CEILING TO...
  • Page 42: Appliance Service History

    APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 42 39813-1-0919...
  • Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 39813-1-0919 Page 43...
  • Page 44: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods specified below. Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.

Table of Contents