Overview; Features - Mitsubishi MELSEC-Q Q62DAN User Manual

Digital-analog converter module
Hide thumbs Also See for MELSEC-Q Q62DAN:
Table of Contents

Advertisement

1 OVERVIEW

1 OVERVIEW
This User's Manual provides the specifications, handling instructions and
programming methods for the following digital-analog converter modules that are
used in combination with MELSEC-Q series CPU modules (hereinafter referred to as
programmable controller CPU).
• Q62DAN type digital-analog converter module (hereinafter referred to as the Q62DAN)
• Q64DAN type digital-analog converter module (hereinafter referred to as the Q64DAN)
• Q68DAVN type digital-analog converter module (hereinafter referred to as the Q68DAVN)
• Q68DAIN type digital-analog converter module (hereinafter referred to as the Q68DAIN)
• Q62DA type digital-analog converter module (hereinafter referred to as the Q62DA)
• Q64DA type digital-analog converter module (hereinafter referred to as the Q64DA)
• Q68DAV type digital-analog converter module (hereinafter referred to as the Q68DAV)
• Q68DAI type digital-analog converter module (hereinafter referred to as the Q68DAI)
In this manual, the Q62DAN, Q64DAN, Q68DAVN, Q68DAIN, Q62DA, Q64DA,
Q68DAV and Q68DAI are collectively referred to as the D/A (Digital-Analog) converter
modules.

1.1 Features

(1) Available models
(2) Improved security and noise immunity (Q62DAN, Q64DAN,
(3) High-speed conversion processing
(4) High degree of accuracy
(5) Changing the resolution mode
(6) Changing the output range
(7) Synchronous output function
1 - 1
• Q62DAN, Q62DA ............. 2 channels: Voltage or current output can be selected for
• Q64DAN, Q64DA ............. 4 channels: Voltage or current output can be selected for
• Q68DAVN, Q68DAV ........ 8 channels: All of which are voltage output.
• Q68DAIN, Q68DAI ........... 8 channels: All of which are current output.
Q68DAVN, Q68DAIN only)
isolation is provided between the external power supply and
Since
analog output channels, the
increased.
Conversion processing is performed at a speed of 80
The conversion accuracy is ± 0.1% (When the ambient temperature is 25 ± 5 °C).
The resolution mode can be changed according to the application, and digital-
value resolution settings of 1/4000, 1/12000 or 1/16000 can be selected.
1
The output range
can easily be changed using GX Developer.
1 The output range refers to the type of offset/gain settings. The most
frequently used range is set as the default but the user can also specify their
own offset/gain settings.
This function sets a constant time (120
the digital value is written from the programmable controller CPU. Highly
accurate analog control can be achieved by combining this function with a
constant cycle execution type program for the programmable controller CPU or
the constant scan function
2 The constant scan function executes the sequence program within a
fixed time interval.
each channel.
each channel.
security and noise immunity have been
s) until the analog value is output after
2
.
MELSEC-Q
s/channel.