Dual Fuel Ranges
Planning Information
When installing against a combustible surface, a minimum
254 mm riser is required for a 91 cm Wolf Dual Fuel Range
with charbroiler or griddle and all 122 cm and 152 cm
models. Follow all minimum clearances to combustible
surfaces shown in the illustration on the following page.
A Wolf Pro Ventilation Hood is recommended with the
Wolf Dual Fuel Range. Refer to Pro Ventilation on page
106.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 30 or 50
amps (refer to the chart below), and must include 3 or 4
conductors.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS
ELECTRICAL SUPPLY
Single Phase
3-Phase
MAX CONNECTED LOAD
76 cm Range
91 cm Range
122 cm Range
152 cm Range
220–240 V AC, 50/60 Hz
380–415 V AC, 50 Hz
SINGLE PHASE
3-PHASE
20.5 A
19.2 A
20.5 A
19.2 A
38.9 A
19.2 A
40.8 A
19.2 A