Wolf M Series Design Manual page 53

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

Module Cooktops
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations on
the following pages. A separate circuit servicing only this
appliance is required.
The induction cooktop is supplied with a single phase and
3-phase convertible power inlet box.
When multiple cooktops or Modules are installed side by
side, each must have its own separate electrical supply.
ELECTRICAL REQUIREMENTS
INDUCTION MODULE
Single Phase
3-Phase
Total Amps
ELECTRIC MODULES
Electrical Supply
Steamer
Grill
GAS MODULES
Electrical Supply
Service
Receptacle
Power Cord
DRAIN OUTLET
The Steamer Module requires a method for draining hot
water. Options include connecting a drain hose from the
16 mm outlet tied into an existing drain, a separate drain
with freefall, or placing a heat-resistant receptacle under
the drain outlet.
220-240 VAC, 50/60 Hz
380-415 V AC, 50 Hz
16
220-240 VAC, 50/60 Hz
2700 W
2800 W
220-240 VAC; 50/60 Hz
0.2 A
grounding-type (earthed)
1.8 m
GAS SUPPLY
Installation must conform with all applicable gas codes.
For gas Modules, a gas supply line of 19 mm rigid pipe
must be provided to the module. If local codes permit,
a certified, .9 m long, 13 mm or 19 mm ID flexible metal
appliance connector is recommended to connect the units
1/2" NPT (or ISO 7/1-14) male inlet to the gas supply line.
When multiple Gas Cooktops or Modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or Module.
Wolf natural gas cooktops will function up to 3124 m in
altitude without adjustment and LP gas cooktops will func-
tion up to 2621 m. If the installation exceeds these eleva-
tions, contact an authorized Wolf dealer for a high altitude
conversion kit.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
LP GAS
Supply Pressure
WC
25 mbar
WC
37 mbar
subzero.com | 53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents