Wolf M Series Design Manual
Wolf M Series Design Manual

Wolf M Series Design Manual

Hide thumbs Also See for M Series:

Advertisement

Design Guide
ICB REVISED 7/2022

Advertisement

Table of Contents
loading

Summary of Contents for Wolf M Series

  • Page 1 Design Guide ICB REVISED 7/2022...
  • Page 2: Table Of Contents

    Contents Contents M Series Ovens E Series Ovens Convection Steam Ovens Speed Ovens Warming Drawers Induction Cooktops Gas Cooktops Module Cooktops Coffee Systems Cup Warming Drawers Vacuum Seal Drawer Dual Fuel Ranges Induction Ranges Sealed Burner Rangetops Outdoor Grills | Modules | Accessories...
  • Page 3: M Series Ovens

    TRANSITIONAL system, touch-screen controls, convenient preset cooking programs, and improved interior lighting. There is more usable space inside for deliciousness on a grand scale. M Series Ovens can be installed in a standard or flush inset application. ICBSO30TM/S/TH ICBDO30TM/S/TH PROFESSIONAL...
  • Page 4 M Series Ovens M Series Built-In Ovens TRANSITIONAL SINGLE OVEN 46 mm 51 mm 36 mm CONDUIT CHANNEL 724 mm 759 mm 584 mm BEHIND FRAME OPEN OVEN DOOR TRANSITIONAL DOUBLE OVEN 46 mm 51 mm 36 mm CONDUIT CHANNEL...
  • Page 5 M Series Ovens M Series Built-In Ovens PROFESSIONAL SINGLE OVEN 46 mm 51 mm 36 mm CONDUIT CHANNEL 724 mm 759 mm 584 mm BEHIND FRAME OPEN OVEN DOOR PROFESSIONAL DOUBLE OVEN 46 mm 51 mm 36 mm CONDUIT CHANNEL...
  • Page 6 M Series Ovens M Series Built-In Ovens CONTEMPORARY STAINLESS STEEL SINGLE OVEN 46 mm 36 mm CONDUIT CHANNEL 724 mm 759 mm 584 mm BEHIND FRAME OPEN OVEN DOOR CONTEMPORARY STAINLESS STEEL DOUBLE OVEN 46 mm 36 mm CONDUIT CHANNEL...
  • Page 7 M Series Ovens M Series Built-In Ovens CONTEMPORARY BLACK GLASS SINGLE OVEN 46 mm 51 mm 36 mm CONDUIT CHANNEL 724 mm 759 mm 584 mm BEHIND FRAME OPEN OVEN DOOR CONTEMPORARY BLACK GLASS DOUBLE OVEN 46 mm 51 mm...
  • Page 8 M Series Ovens Planning Information The M Series Oven can be installed in a standard or flush DUAL INSTALLATION inset application. If a cooktop is installed above an oven, a Two 76 cm single M Series Ovens can be installed side by minimum of 6 mm is required between the units.
  • Page 9 M Series Ovens Planning Information ELECTRICAL REQUIREMENTS ELECTRICAL REQUIREMENTS—SINGLE OVEN ELECTRICAL SUPPLY Installation must comply with all applicable electrical Single Phase 220–240 V AC, 50/60 Hz codes and be properly grounded (earthed). 3-Phase 380–415 V AC, 50 Hz Locate the electrical supply flush with the back wall and...
  • Page 10 M Series Ovens M Series Single Oven STANDARD INSTALLATION 591 mm OPENING DEPTH TOP VIEW 699 mm 724 mm OPENING HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 10 | English...
  • Page 11 M Series Ovens M Series Single Oven FLUSH INSET INSTALLATION 22 mm 610 mm FLUSH INSET 25 mm DEPTH FINISHED CLEATS* TOP VIEW 765 mm FLUSH INSET WIDTH*** 29 mm 730 mm FLUSH INSET HEIGHT*** 21 mm 3 mm SIDE VIEW FRONT VIEW *25 mm minimum depth.
  • Page 12 M Series Ovens M Series Double Oven STANDARD INSTALLATION 591 mm OPENING DEPTH TOP VIEW 1267 mm 724 mm OPENING HEIGHT OPENING WIDTH 432 mm TYPICAL SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth.
  • Page 13 M Series Ovens M Series Double Oven FLUSH INSET INSTALLATION 22 mm 610 mm FLUSH INSET 25 mm DEPTH FINISHED CLEATS* TOP VIEW 765 mm FLUSH INSET WIDTH*** 29 mm 1299 mm FLUSH INSET HEIGHT*** 21 mm 3 mm 432 mm...
  • Page 14 M Series Ovens M Series Single Oven DUAL STANDARD INSTALLATION 591 mm OPENING DEPTH TOP VIEW 699 mm OPENING 1486 mm HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
  • Page 15 M Series Ovens M Series Single Oven DUAL FLUSH INSET INSTALLATION 22 mm 610 mm FLUSH INSET 25 mm DEPTH FINISHED CLEATS* TOP VIEW 1527 mm FLUSH INSET WIDTH*** 29 mm 730 mm FLUSH INSET HEIGHT*** 21 mm 3 mm...
  • Page 16: E Series Ovens

    E Series Ovens E Series Built-In Ovens The Wolf E Series Convection Oven has two fans and four E SERIES OVENS heating elements. Ten cooking modes allow you to select TRANSITIONAL the one precisely suited to the dish you’re preparing. The oven is self-cleaning.
  • Page 17 E Series Ovens 60 cm E Series Oven TRANSITIONAL 22 mm 597 mm 546 mm BEHIND FRAME OPEN OVEN DOOR subzero.com | 17...
  • Page 18 E Series Ovens 76 cm E Series Ovens TRANSITIONAL 36 mm CONDUIT CHANNEL 724 mm 759 mm 584 mm BEHIND FRAME OPEN OVEN DOOR PROFESSIONAL 36 mm CONDUIT CHANNEL 724 mm 584 mm 759 mm BEHIND FRAME OPEN OVEN DOOR 18 | English...
  • Page 19 E Series Ovens Planning Information The E series oven can be installed in a standard or flush ELECTRICAL REQUIREMENTS—60 cm OVEN inset application. If a cooktop is installed above an oven, a Installation must comply with all applicable electrical minimum of 6 mm is required between the units. The loca- codes and be properly grounded (earthed).
  • Page 20 E Series Ovens 60 cm E Series Oven STANDARD INSTALLATION 584 mm OPENING DEPTH TOP VIEW OPENING HEIGHT 553 mm OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 20 | English...
  • Page 21 E Series Ovens 60 cm E Series Oven FLUSH INSET INSTALLATION 610 mm FLUSH INSET 22 mm DEPTH FINISHED CLEATS* TOP VIEW 10 mm 603 mm FLUSH INSET HEIGHT** 25 mm 3 mm 603 mm FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry.
  • Page 22 E Series Ovens 76 cm E Series Oven STANDARD INSTALLATION 591 mm OPENING DEPTH TOP VIEW 699 mm 724 mm OPENING HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. 22 | English...
  • Page 23 E Series Ovens 76 cm E Series Oven FLUSH INSET INSTALLATION 610 mm FLUSH INSET 22 mm DEPTH FINISHED CLEATS* TOP VIEW 765 mm FLUSH INSET WIDTH** 29 mm 730 mm FLUSH INSET HEIGHT** 21 mm 3 mm SIDE VIEW FRONT VIEW *Shaded areas will be visible and should be finished to match cabinetry.
  • Page 24: Convection Steam Ovens

    ICBCSO3050TM/S/T ICBCSO3050TE/S/T prepared in a conventional oven, range, or microwave can ICBCSOP2450TE/S/T also be prepared in the Wolf Convection Steam Oven— PROFESSIONAL with more control. Two widths and three distinct styles compliment the look of Wolf ovens, ranges, and cooktops.
  • Page 25 Convection Steam Ovens Convection Steam Ovens TRANSITIONAL 22 mm 546 mm BEHIND FRAME WIDTH OPEN OVEN DOOR WIDTH 60 cm Transitional 597 mm 546 mm 76 cm Transitional 759 mm 721 mm PROFESSIONAL 721 mm 22 mm 546 mm 759 mm BEHIND FRAME OPEN OVEN DOOR subzero.com | 25...
  • Page 26 Convection Steam Ovens Convection Steam Ovens CONTEMPORARY 22 mm 721 mm 759 mm 546 mm BEHIND FRAME OPEN OVEN DOOR CONTEMPORARY HANDLELESS 22 mm 546 mm WIDTH BEHIND FRAME OPEN OVEN DOOR WIDTH 60 cm Contemporary Handleless 597 mm 546 mm 76 cm Contemporary Handleless 759 mm 721 mm...
  • Page 27 Convection Steam Ovens Planning Information The Convection Steam Oven can be installed in a standard ELECTRICAL REQUIREMENTS or flush inset application. The back of the base support Installation must comply with all applicable electrical must be open for water and drain line accessibility and codes and be properly grounded (earthed).
  • Page 28 Convection Steam Ovens Plumbing Requirements MODEL ICBCSOP2450TE/S/T Connect the water supply to a cold water house supply with an easily accessible shut-off valve between the supply Installation must comply with all applicable plumbing and the unit. codes. Purge the water supply prior to final connection to the The drain tube connection must be a minimum 51 mm unit.
  • Page 29 Convection Steam Ovens Convection Steam Oven STANDARD INSTALLATION 584 mm OPENING DEPTH TOP VIEW OPENING HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. OPENING WIDTH 60 cm Model 553 mm 76 cm Model 727 mm subzero.com | 29...
  • Page 30 Convection Steam Ovens Convection Steam Oven FLUSH INSET INSTALLATION 610 mm FLUSH INSET 22 mm DEPTH FINISHED CLEATS* TOP VIEW 8 mm FLUSH INSET HEIGHT** 3 mm FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
  • Page 31: Speed Ovens

    Speed Ovens Speed Ovens The Wolf Speed Oven has features that make fast meals SPEED OVENS better meals. Available in 60 cm and 76 cm widths, they TRANSITIONAL are designed to match Wolf transitional, professional, and contemporary products. The Speed Oven can be installed in a standard or flush inset application.
  • Page 32 Speed Ovens Speed Ovens TRANSITIONAL 22 mm 538 mm 546 mm BEHIND FRAME WIDTH OPEN OVEN DOOR WIDTH 60 cm Transitional 597 mm 76 cm Transitional 759 mm PROFESSIONAL 538 mm 22 mm 759 mm 546 mm BEHIND FRAME OPEN OVEN DOOR CONTEMPORARY 538 mm...
  • Page 33 90°. Performance may be compromised if the electrical supply is less than 220 volts. If the Speed Oven is installed above or below a Wolf E Series Oven in a flush inset application, a 6 mm reveal is ELECTRICAL REQUIREMENTS required.
  • Page 34 Speed Ovens Speed Oven STANDARD INSTALLATION 584 mm OPENING DEPTH TOP VIEW OPENING HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: 60 cm and 76 cm models require the same opening dimensions. OPENING WIDTH 60 cm Model 562 mm 76 cm Model 562 mm 34 | English...
  • Page 35 Speed Ovens Speed Oven FLUSH INSET INSTALLATION 610 mm FLUSH INSET 22 mm DEPTH FINISHED CLEATS* TOP VIEW 8 mm FLUSH INSET HEIGHT** 3 mm FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
  • Page 36: Warming Drawers

    Warming Drawers Warming Drawers Wolf Warming Drawers are designed to take care of WARMING DRAWER FRONTS prepared foods until it is time to serve them. You can M SERIES adjust the temperature, keeping moist foods moist and crisp foods crisp. Warming Drawers are ideal for proofing dough.
  • Page 37 718 mm properly with the front of the rangetop. Dimensions for the Warming Drawer remain the same, even though the drawer front may be wider to match a Wolf 91 cm Oven or Sealed Burner Rangetop. OPEN DRAWER DRAWER FRONT...
  • Page 38 Warming Drawers Planning Information The Warming Drawer must be installed with a Wolf drawer ELECTRICAL REQUIREMENTS front, avail able through an authorized Wolf dealer. Specific Installation must comply with all applicable electrical installation instructions are included with the drawer front.
  • Page 39 Warming Drawers Warming Drawer STANDARD INSTALLATION 584 mm OPENING DEPTH TOP VIEW ANTI-TIP BLOCK 232 mm OPENING HEIGHT 727 mm OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. subzero.com | 39...
  • Page 40 *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOTE: Location of electrical supply within opening may require additional cabinet depth. DRAWER FRONT DEPTH (A) M SERIES E SERIES Transitional / Professional 22 mm 29 mm...
  • Page 41: Induction Cooktops

    INDUCTION COOKTOPS wasted heat. Induction cooking has been popular among TRANSITIONAL European chefs and homeowners for decades. Now Wolf leads the way in bringing this remarkable technology to North American kitchens. Its secret is magnetism. Elec- tromagnetic elements cause iron and magnetic stainless...
  • Page 42 Induction Cooktops Induction Cooktops 60 cm TRANSITIONAL 76 cm TRANSITIONAL 91 cm TRANSITIONAL 762 mm 600 mm 914 mm 51 mm 51 mm 51 mm CONDUIT CONDUIT CONDUIT 32 mm 32 mm 32 mm 60 cm CONTEMPORARY 76 cm CONTEMPORARY 91 cm CONTEMPORARY 600 mm 762 mm...
  • Page 43 Induction Cooktops Induction Cooktops Planning Information A minimum height clearance of 159 mm is required from ELEMENT RATING the top of the countertop to any combustible surface 60 cm COOKTOP directly below the cooktop. 279 mm 2600 / 3150 boost 203 mm 2100 / 3000 boost Contemporary Induction Cooktops can be mounted flush...
  • Page 44 Induction Cooktops 60 cm / 76 cm / 91 cm Induction Cooktop STANDARD INSTALLATION 64 mm WIDTH 64 mm COUNTERTOP CUTOUT 114 mm 89 mm 254 mm 914 mm FLOOR TO COUNTERTOP SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
  • Page 45 Induction Cooktops 60 cm / 76 cm / 91 cm Induction Cooktop FLUSH INSTALLATION 64 mm COUNTERTOP PROFILE 537 mm CUTOUT WIDTH RECESS RECESS 8 mm 40 mm 64 mm COUNTERTOP CUTOUT 114 mm 89 mm 254 mm 914 mm FLOOR TO COUNTERTOP SIDE VIEW...
  • Page 46: Gas Cooktops

    Gas Cooktops Gas Cooktops Like their oven counterparts, the new generation of Wolf GAS COOKTOPS Gas Cooktops features two new looks—transitional and TRANSITIONAL professional. New performance enhancements make delicious results even more of a certainty than ever. Mul- tiple sizes, choice of knob colors, and distinctly different grates—the new Gas Cooktops offer exceptional design...
  • Page 47 Gas Cooktops Gas Cooktops 76 cm TRANSITIONAL 91 cm TRANSITIONAL 914 mm 762 mm 102 mm 102 mm 76 cm PROFESSIONAL 91 cm PROFESSIONAL 762 mm 914 mm 102 mm 102 mm 22 mm 22 mm subzero.com | 47...
  • Page 48 Locate the electrical supply as shown in the illustration LP gas. on the following pages. A separate circuit servicing only Wolf natural gas cooktops will function up to 3124 m in this appliance is required. A ground fault circuit interrupter altitude without adjustment and LP gas cooktops will (GFCI) is not recommended and may cause interruption of function up to 2621 m.
  • Page 49 Gas Cooktops 76 cm / 91 cm Cooktop STANDARD INSTALLATION 64 mm WIDTH 64 mm COUNTERTOP CUTOUT 102 mm 89 mm 254 mm SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical and gas supply location only applies to installations with built-in oven.
  • Page 50: Module Cooktops

    Module Cooktops Module Cooktops Wolf 38 cm Modules have been redesigned to match the MODULE COOKTOPS updated lines of Sub-Zero and Wolf. Controls, grates, and trim allow them to integrate perfectly with their larger counterparts and deliver equal performance. Combine Modules à...
  • Page 51 Module Cooktops Module Cooktops INDUCTION STEAMER GRILL 381 mm 51 mm CONDUIT DRAIN OUTLET MULTIFUNCTION 127 mm 22 mm subzero.com | 51...
  • Page 52 Module Cooktops Planning Information IMPORTANT NOTE: Wolf does not recommend the use of MULTIPLE COOKTOPS downdraft ventilation with the Steamer or Grill Modules. When multiple Modules are installed side by side, refer to A minimum 51 mm is required from the bottom of the the chart and illustration below for typical configurations.
  • Page 53 Module. Wolf natural gas cooktops will function up to 3124 m in ELECTRICAL REQUIREMENTS altitude without adjustment and LP gas cooktops will func- INDUCTION MODULE tion up to 2621 m.
  • Page 54 Module Cooktops Induction Module STANDARD INSTALLATION 64 mm 64 mm COUNTERTOP CUTOUT 914 mm FLOOR TO COUNTERTOP SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. 54 | English...
  • Page 55 Module Cooktops Steamer Module STANDARD INSTALLATION 64 mm 64 mm COUNTERTOP CUTOUT DRAIN OUTLET SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. subzero.com | 55...
  • Page 56 Module Cooktops Grill Module STANDARD INSTALLATION 64 mm 64 mm COUNTERTOP CUTOUT SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. 56 | English...
  • Page 57 Module Cooktops Gas / Multifunction Module STANDARD INSTALLATION 64 mm 64 mm COUNTERTOP CUTOUT SIDE VIEW FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. subzero.com | 57...
  • Page 58: Coffee Systems

    It uses either whole-bean or ground coffee. The design pairs beautifully, either side-by-side or in a tower application, with other Wolf products such as the Convection Steam Oven. The ICBEC2450TE/S Coffee System can be installed in a standard or flush inset application.
  • Page 59 Coffee Systems Coffee System DIMENSIONS 483 mm UNIT BEHIND FRAME WIDTH FULL EXTENSION WIDTH 60 cm Model 597 mm 76 cm Trim 759 mm subzero.com | 59...
  • Page 60 Coffee Systems Planning Information The Coffee System can be installed in a standard or flush ELECTRICAL REQUIREMENTS inset application. The sides of the cabinet opening must Installation must comply with all applicable electrical be adequate to support installation of the mounting slides. codes and be properly grounded (earthed).
  • Page 61 Coffee Systems Coffee System STANDARD INSTALLATION SLIDE OPENING SUPPORT DEPTH TOP VIEW 449 mm SLIDE OPENING SUPPORT HEIGHT OPENING WIDTH SIDE VIEW FRONT VIEW NOTE: 610 mm model and model with 762 mm trim require the same opening dimensions. OPENING WIDTH 60 cm Model 562 mm 76 cm Trim...
  • Page 62 Coffee Systems Coffee System FLUSH INSET INSTALLATION 584 mm SLIDE FLUSH SUPPORT INSET 22 mm DEPTH FINISHED CLEATS* TOP VIEW 8 mm 460 mm SLIDE FLUSH INSET SUPPORT HEIGHT** 3 mm FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
  • Page 63: Cup Warming Drawers

    Wolf Cup Warming Drawers preheat cups so hot beverages DIMENSIONS stay hot longer. The temperature is adjustable. Two model options match the look of Wolf stainless and black Coffee Systems. Cup Warming Drawers can be installed in a stan- dard or flush inset application.
  • Page 64 Cup Warming Drawer Planning Information The Cup Warming Drawer can be installed in a standard ELECTRICAL REQUIREMENTS or flush inset application. Finish the edges of the opening. Installation must comply with all applicable electrical They may be visible when the drawer is open. codes and be properly grounded (earthed).
  • Page 65 Cup Warming Drawer Cup Warming Drawer STANDARD INSTALLATION 533 mm OPENING DEPTH TOP VIEW ANTI-TIP BLOCK 140 mm OPENING HEIGHT 562 mm OPENING WIDTH SIDE VIEW FRONT VIEW subzero.com | 65...
  • Page 66 Cup Warming Drawer Cup Warming Drawer FLUSH INSET INSTALLATION 558 mm FLUSH INSET 25 mm DEPTH*** FINISHED CLEATS* TOP VIEW 3 mm ANTI-TIP BLOCK 146 mm 3 mm FLUSH INSET HEIGHT** 603 mm FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry.
  • Page 67: Vacuum Seal Drawer

    Vacuum Seal Drawer Vacuum Seal Drawer The Vacuum Seal Drawer can be installed in a standard DIMENSIONS or flush inset application. Stainless steel, black glass, and integrated drawer fronts are available in 61 cm and 76 cm widths. The integrated drawer front allows for a custom panel.
  • Page 68 Vacuum Seal Drawer Planning Information The Vacuum Seal Drawer can be installed in a standard or ELECTRICAL REQUIREMENTS flush inset application. Finish the edges of the opening. Installation must comply with all applicable electrical They may be visible when the drawer is open. codes and be properly grounded (earthed).
  • Page 69 Vacuum Seal Drawer Vacuum Seal Drawer STANDARD INSTALLATION 533 mm OPENING DEPTH TOP VIEW ANTI-TIP BLOCK 141 mm OPENING HEIGHT 562 mm OPENING WIDTH SIDE VIEW FRONT VIEW subzero.com | 69...
  • Page 70 Vacuum Seal Drawer Vacuum Seal Drawer FLUSH INSET INSTALLATION 558 mm FLUSH INSET 22 mm DEPTH*** FINISHED CLEATS* TOP VIEW 2 mm ANTI-TIP BLOCK 146 mm 3 mm FLUSH INSET HEIGHT** FLUSH INSET WIDTH** SIDE VIEW FRONT VIEW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
  • Page 71: Dual Fuel Ranges

    Dual Fuel Ranges Dual Fuel Ranges Discover a new world of cooking—the best of two worlds, CONFIGURATIONS actually—with a Wolf Dual Fuel Range. Topside, gas cook- 76 cm RANGE 122 cm RANGE 152 cm RANGE ing in all its glory, with the fine control of dual-stacked, sealed burners and options including charbroiler and griddle.
  • Page 72 Dual Fuel Ranges Overall Dimensions 749 mm 749 mm 683 mm 683 mm 76 cm RANGE 91 cm RANGE 122 cm RANGE 610 mm 610 mm 660 mm 660 mm 759 mm 911 mm 1216 mm 1200 mm 1200 mm *902 mm 965 mm *902 mm...
  • Page 73 When installing against a combustible surface, a minimum ELECTRICAL REQUIREMENTS 254 mm riser is required for a 91 cm Wolf Dual Fuel Range Installation must comply with all applicable electrical with charbroiler or griddle and all 122 cm and 152 cm codes and be properly grounded (earthed).
  • Page 74 ISO 7/1-14 female inlet to the gas supply line. Wolf natural gas ranges will function up to 3124 m in altitude without adjustment and LP gas ranges will func- tion up to 2621 m. If the installation exceeds these eleva- tions, contact an authorized Wolf dealer for a high altitude conversion kit.
  • Page 75 Dual Fuel Ranges Dual Fuel Range INSTALLATION 762 mm 914 mm TO BOTTOM OF VENTILATION HOOD OPENING WIDTH 937 mm TO COOKING SURFACE ELECTRICAL AND GAS IN ‘A’ LOCATION ONLY SIDE VIEW FRONT VIEW *Without ventilation hood, 914 mm minimum clearance countertop to combustible materials, 1118 mm for charbroiler. NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
  • Page 76: Induction Ranges

    Induction Ranges Induction Ranges Experience a new way of cooking with a Wolf Induction CONFIGURATIONS Range. Magnetism allows the ultrafast, energy efficient 76 cm RANGE 91 cm RANGE surface elements to heat up instantly and with perfectly distributed heat. Heat generation stops the instant you turn off the element or remove the pan.
  • Page 77 Induction Ranges Overall Dimensions 718 mm 718 mm 76 cm RANGE 91 cm RANGE 699 mm 699 mm 616 mm 616 mm 667 mm 667 mm 759 mm 911 mm 1200 mm 1200 mm *902 mm 965 mm *902 mm 965 mm MIN TO MIN TO...
  • Page 78 Induction Range Planning Information Follow all minimum clearances to combustible surfaces ELECTRICAL REQUIREMENTS shown in the illustration on the following page. Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the wall or floor and within the shaded area shown in the illustration on the following page.
  • Page 79 Induction Range Induction Range INSTALLATION 762 mm 914 mm TO BOTTOM OF VENTILATION HOOD OPENING WIDTH 914 mm TO COOKING SURFACE ELECTRICAL IN ‘A’ LOCATION ONLY SIDE VIEW FRONT VIEW *Without ventilation hood, 914 mm minimum clearance countertop to combustible materials. NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
  • Page 80: Sealed Burner Rangetops

    Sealed Burner Rangetops Sealed Burner Rangetops Wolf Sealed Burner Rangetops incorporate all the gas CONFIGURATIONS cooking features of a Wolf Dual Fuel Range. Customize 91 cm RANGETOP 122 cm RANGETOP your rangetop with your preferred combination of burners, infrared griddle, charbroiler, or wok burner.
  • Page 81 Sealed Burner Rangetops 724 mm 699 mm Sealed Burner Rangetops 445 mm 91 cm RANGETOP 318 mm 613 mm 911 mm 664 mm 724 mm 699 mm 445 mm 122 cm RANGETOP 318 mm 613 mm 1216 mm 664 mm SIDE VIEW—ALL RANGETOPS subzero.com | 81...
  • Page 82 ISO 7/1-14 female inlet to the gas supply line. Wolf natural gas rangetops will function up to 3124 m in altitude without adjustment and LP gas ranges will func- tion up to 2621 m. If the installation exceeds these eleva- tions, contact an authorized Wolf dealer for a high altitude conversion kit.
  • Page 83 Sealed Burner Rangetops Sealed Burner Rangetop INSTALLATION 762 mm 914 mm TO BOTTOM OF VENTILATION HOOD 191 mm OPENING OPENING WIDTH HEIGHT 610 mm PLATFORM PLATFORM PLATFORM TOP VIEW 406 mm ELECTRICAL AND GAS SIDE VIEW FRONT VIEW *Without ventilation hood, 914 mm minimum clearance countertop to combustible materials, 1118 mm for charbroiler. NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
  • Page 84: Outdoor Grills | Modules | Accessories

    137 cm Grill, can be used on a cart for portable convenience. The 25,000 Btu Burner Module can be built into an outdoor kitchen and the Side Burner attached to a cart. Wolf Grills and Modules can be ordered in natural or LP gas. ICBOG54...
  • Page 85 Outdoor Grills | Modules Outdoor Grills and Modules OUTDOOR GRILL HOOD CLOSED GRILLING CLEARANCE SURFACE FOR OPEN HOOD WIDTH GRILL CART TO GRILL PLATFORM WIDTH MAX DOOR/DRAWER CLEARANCE BURNER MODULE / SIDE BURNER OUTDOOR GRILL ICBOG30 762 mm ICBOG36 914 mm ICBOG42 1067 mm ICBOG54...
  • Page 86 ELECTRICAL REQUIREMENTS (GRILL / MODULE) mum of 305 mm is required between the units. A rotisserie Electrical Supply grounded, 220-240 VAC, 50/60 Hz side conversion kit is available from an authorized Wolf Service dealer. Receptacle 3-prong grounding-type (earthed), IEC inlet Optional stainless steel accessory doors and drawers are available for built-in applications.
  • Page 87 NAT or LP gas sources. For local dealer information, visit our website, wolfappliance.com. If the Outdoor Grill is being connected to a whole house LP supply, the LP gas pressure regulator is not provided. It can be purchased from an authorized Wolf dealer. GAS REQUIREMENTS NATURAL GAS Supply Pressure 12.5 mbar...
  • Page 88 Outdoor Grills | Modules Outdoor Grill NON-COMBUSTIBLE INSTALLATION COMBUSTIBLE INSTALLATION 305 mm 64 mm 616 mm 660 mm GRILL LINER OPENING OVERLAP OPENING OVERLAP DEPTH DEPTH 70 mm KNOCKOUT TOP VIEW TOP VIEW OPENING WIDTH OPENING WIDTH OPENING OPENING 102 mm HEIGHT HEIGHT GRILL...
  • Page 89 Outdoor Grills | Modules Burner Module INSTALLATION 305 mm 76 mm 616 mm MODULE OPENING OVERLAP DEPTH TOP VIEW 305 mm OPENING 254 mm OPENING HEIGHT MODULE OPENING COUNTERTOP OVERHANG FRONT VIEW NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
  • Page 90 Outdoor Accessories Outdoor Accessories ACCESS DOORS SINGLE DOUBLE ACCESSORY DRAWERS AND DOORS SINGLE DRAWER 2- OR 3-DRAWER DOOR/DRAWER PAPER TOWEL DRAWER SHORT DRY STORAGE TALL DRY STORAGE TRASH/RECYCLING DRAWER 90 | English...
  • Page 91 Outdoor Accessories Access Doors DIMENSIONS INSTALLATION 89 mm FINISHED 70 mm RETURN TOP VIEW GRILL OPENING 25 mm 483 mm OPENING HEIGHT DOOR WIDTH OPENING WIDTH 46 cm Single 457 mm 413 mm FRONT VIEW 76 cm Double 762 mm 718 mm 91 cm Double 914 mm...
  • Page 92 Outdoor Accessories Accessory Drawers and Doors SINGLE DRAWER 2- OR 3-DRAWER 686 mm 305 mm 70 mm 70 mm 762 mm 330 mm PAPER TOWEL DRAWER 368 mm DRAWER/DOOR 724 mm 70 mm 457 mm 70 mm 203 mm 762 mm 92 | English...
  • Page 93 Outdoor Accessories Accessory Drawers and Doors TALL DRY STORAGE TRASH/RECYCLE DRAWER 559 mm 406 mm 70 mm 70 mm 610 mm 457 mm DEPTH Single 495 mm SHORT DRY STORAGE Double 572 mm 864 mm 70 mm 914 mm subzero.com | 93...
  • Page 94 Outdoor Accessories Accessory Drawers and Doors INSTALLATION OPENING Single Drawer 692 mm 248 mm 616 mm Paper Towel Drawer 375 mm 210 mm 489 mm 2- or 3-Drawer 311 mm 489 mm 464 mm Drawer/Door 730 mm 489 mm 464 mm Tall Dry Storage 565 mm 819 mm...
  • Page 95 Cooktop Hoods Cooktop Ventilation Hoods The new generation of Wolf Cooktop Ventilation Hoods COOKTOP VENTILATION HOODS feature two new looks—black and stainless. Brilliant LED BLACK lighting illuminates your cooking surface while powerful multi-speed blowers whisk away smoke and odors. The dishwasher-safe filters can be removed easily for cleaning.
  • Page 96 Cooktop Hoods Cooktop Ventilation Hoods WALL HOODS—BLACK 298 mm 260 mm 740 mm 997 mm* 57 mm 914 mm 489 mm *1248 mm to 1505 mm with accessory flue extension. ISLAND HOOD—BLACK 349 mm 286 mm 591 mm 813 mm* 57 mm 1067 mm 673 mm...
  • Page 97 Cooktop Hoods Cooktop Ventilation Hoods WALL HOODS—STAINLESS 298 mm 260 mm 740 mm 997 mm* 559 mm WIDTH *1248 mm to 1505 mm with accessory flue extension. WIDTH ICBVW30S 762 mm ICBVW36S 914 mm ISLAND HOOD—STAINLESS 349 mm 286 mm 591 mm 813 mm* 1067 mm...
  • Page 98 ELECTRICAL REQUIREMENTS with Wolf Induction and Gas Cooktops, and Modules. For Installation must comply with all applicable electrical Wolf Ranges and Rangetops, a Wolf Pro Ventilation hood is codes and be properly grounded (earthed). recommended. For wall hoods, locate the electrical supply within the These hoods have a telescopic chimney flue.
  • Page 99 Cooktop Hoods Ceiling-Mounted Hood The new Ceiling-Mounted Hood is our most contemporary CEILING-MOUNTED HOODS ventilation offering, nearly disappearing into its surround- ings. It comes in two widths and is available in stainless steel. The hood ships with a remote control and can be operated using the remote control or the control panel.
  • Page 100: Cooktop Ventilation

    The hood is shipped without a blower assembly. A 900 through an authorized Wolf dealer, is required. CMH internal blower is avail able through an authorized Wolf dealer. Refer to Ventilation Suggestions on pages 110–112. The Ceiling-Mounted Hood includes a 152 mm round discharge for the internal blower.
  • Page 101 Cooktop Ventilation Planning Information Opening Dimensions ELECTRICAL REQUIREMENTS CEILING-MOUNTED HOOD Installation must comply with all applicable electrical Refer to the chart and illustrations below for opening codes and be properly grounded (earthed). dimensions and typical framing. Framing must be able to support a minimum of 45 kg.
  • Page 102: Downdraft Ventilation

    Downdraft Systems Downdraft Ventilation Downdraft Constructed of heavy duty stainless steel, the Wolf Down- DIMENSIONS draft rises from the countertop to whisk away odor and 51 mm smoke into stainless steel, mesh filters and can be lowered DOWNDRAFT WIDTH beneath the countertop when not in use.
  • Page 103 Installation must comply with all applicable electrical Modules. Contact an authorized Wolf dealer for details. codes and be properly grounded (earthed). For installation with a Wolf Cooktop, a minimum 638 mm Locate the electrical supply as shown in the illustrations deep flat countertop is required.
  • Page 104 Downdraft Systems Downdraft INSTALLATION WITH STANDARD INSTALLED COOKTOP DOWNDRAFT CUTOUT WIDTH 68 mm 210 mm COOKTOP CUTOUT TOP VIEW SIDE VIEW FRONT VIEW *152 mm back from countertop cutout when internal blower is rear mounted. NOTE: Internal blower 152 mm round, side, rear or bottom discharge. Remote blower 254 mm round, rear discharge. Centerline indicates center of downdraft cutout.
  • Page 105 Downdraft Systems Downdraft INSTALLATION WITH FLUSH INSTALLED COOKTOP DOWNDRAFT CUTOUT WIDTH 59 mm 210 mm* COOKTOP CUTOUT TOP VIEW SIDE VIEW FRONT VIEW *152 mm back from countertop cutout when internal blower is rear mounted. NOTE: Internal blower 152 mm round, side, rear, or bottom discharge. In-line and remote blower 254 mm round, rear discharge. Centerline indicates center of downdraft cutout.
  • Page 106: Pro Ventilation

    Pro Ventilation Pro Ventilation Hoods Professional heritage shines through in Wolf professional- PRO HOODS style ventilation. Exteriors are heavy-duty, welded stainless WALL HOODS steel, so finely hand-finished that they appear seamless. Pro Wall Hoods are available in 61 cm and 69 cm depths and a variety of widths.
  • Page 107 Pro Ventilation Pro Hoods 61 cm DEEP WALL HOOD 102 mm 610 mm WIDTH 69 cm DEEP WALL HOOD 102 mm 686 mm WIDTH WIDTH 61 cm DEEP WALL HOOD 914 mm, 1219 mm 69 cm DEEP WALL HOOD 762 mm, 914 mm, 1067 mm, 1219 mm, 1524 mm subzero.com | 107...
  • Page 108 Remote blowers are available through an Electrical Supply 220-240 V AC, 50 Hz 220 V AC, 60 Hz authorized Wolf dealer. The blower will vary in size and is dictated by the cooking unit, volume of air, and length of Service 1.9 A the duct run.
  • Page 109 Pro Ventilation Installation 61 cm / 69 cm DEEP WALL HOODS 762 mm 914 mm BOTTOM EDGE TO COUNTERTOP subzero.com | 109...
  • Page 110: Ventilation Suggestions

    Hood and Downdraft. appliance, CMH requirements, and homeowner prefer- Refer to the illustrations below for the dimensions of Wolf ences. Internal and remote blowers are avail able through remote blowers. Installation instructions shipped with each an authorized Wolf dealer.
  • Page 111 Ventilation Suggestions Wolf Product CMH COOKTOP HOOD DOWNDRAFT PRO HOOD COOKTOP / MODULE ICBCI152TF/S ICBCG152TF/S 1528 ICBSM15TF/S ICBGM15TF/S 1528 ICBMM15TF/S 1528 ICBCI243TF/S ICBCI243C/B 1528 ICBCI304TF/S 1528 ICBCI304C/B 1528 ICBCG304T/S ICBCG304P/S 1528 ICBCI365TF/S 1528 ICBCI365C/B 1528 ICBCG365T/S ICBCG365P/S 1528 DUAL FUEL RANGE...
  • Page 112 Ventilation Suggestions Wolf Ventilation Blower Options BLOWER INTERNAL REMOTE 1528 2028 2535 COOKTOP HOOD • • ICBVW36B ICBVI42B ICBVW30S ICBVW36S ICBVI42S • • • • ICBVC36S ICBVC48S • DOWNDRAFT ICBDD36 • • • • PRO 61 cm DEEP WALL HOOD ICBPW362418 •...
  • Page 113 Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
  • Page 114 LIMITED THIRD THROUGH FIFTH YEAR WARRANTY For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defec- tive in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators.
  • Page 115 FULL ONE YEAR WARRANTY** For one year from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise specified by Wolf Appliance, Inc.
  • Page 116 WOLFAPPLIANCE.COM...

Table of Contents