4.4.2

Removing a GBIC Optical Port

To remove an GBIC optical port, do the following:
Electrical hazard – risk of damage to equipment
Make sure all electrostatic energy is dissipated before performing installing or
removing components from the device. An electrostatic discharge (ESD) can cause
serious damage to the component once it is outside the chassis.
1.
2.
3.
4.
5.
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20
NOTICE
Make sure all potential electrostatic build-up has been properly discharged to
prevent an electrostatic discharge (ESD). This can be accomplished by wearing
an ESD-preventive wrist trap connected to either the chassis ground connector
or a bare metal surface on the router/switch.
Disconnect the cable from the port and install the dust cap to the cable end.
Squeeze the latches on either side of the port and pull it from the socket.
Socket
1
GBIC Optical Port
2
Locking Latch
3
Figure 4.11
Removing a GBIC Optical Port
Store the port in an ESD-safe bag or other suitable ESD-safe environment, free
from moisture and stored at the proper temperature (-40 to 85 °C or -40 to 185
°F).
Insert a dust plug into the socket opening to prevent the ingress of dust and dirt.