HV Impulse
Oscillatory
Magnetic Field
Environmental Type Tests
60068-2-1
60068-2-2
60068-2-30
60068-21-1
60068-21-2
60068-2-78
60068-2-14
60255-21-2
60255-21-3
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20
Description
Signal Ports
DC Power Ports
AC Power Ports
Dielectric
Signal Ports
Strength
DC Power Ports
AC Power Ports
Damped
Enclosure Ports
Test
IEC
Cold Temperature
IEC
Dry Heat
IEC
Humidity (Damp
Heat, Cyclic)
IEC
IEC
IEC
Humidity (Damp
Heat, Steady State)
IEC
Change of Temperature
IEC
IEC
6.2 EMC and Environmental Type Tests
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Cab
Test Nb
Bump
Seismic
Test Levels
1 kV differential mode @ 1 MHz
5 kV (Fail-Safe Relay Output)
5 kV
5 kV
2 kV
2 kV
2 kV
100 A/m
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2g @ 10-150 Hz
30 g @ 11 ms
10 days @ 55 °C (131 °F)
and 93% Relative Humidity
5 Cycles, -40 to 85°
C (40 to 185° F)
10 g @ 16 ms
Method A, Class 2
Certification
Severity
Level
 
 
 
 
 
 
 
Class 1
Class 1
45