Technical Specifications

This section details the specifications and operating conditions of the device.
5.1

Power Supply Specifications

The RUGGEDCOM RSG2100 can be equipped with the following power supplies:
Electrical hazard – risk of power supply failure or damage to the device
Make sure power input to the device is within the specified input range. If power
input is too high, damage to the power supply may occur. If power input is too low,
damage to the device may occur.
HI (125/250 VDC)
HI (110/230 VAC)
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
The HI power supply is the same power supply for both AC and DC.
5.2

Failsafe Relay Specifications

Maximum Switching
Voltage
Rated Switching
Current
Maximum Switching
Capacity
RUGGEDCOM RSG2100
Installation Manual, 11/2022, C79000-G8976-1040-20
NOTICE
Power
Supply Type
Minimum
24 VDC
10 VDC
48 VDC
36 VDC
d
88 VDC
d
85 VAC
250 VAC, 125 VDC
2 A @ 250 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
150 W, 500 VA
Input Range
Maximum
36 VDC
72 VDC
300 VDC
264 VAC
Internal Fuse
Maximum Power
ab
Rating
Consumption
6.3 A(F)
28 W
3.15 A(T)
3.15 A(T)
3.15 A(T)
5
c
31