Siemens SIMATIC NET RUGGEDCOM RSG2100 Installation Manual page 53

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2100:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
IEC 61000-4-17
IEC 61000-4-18
IEC 61000-4-29
IEC 60255-27
a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
Note
RUGGEDCOM products meet Class 1 requirements for copper Ethernet
configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
Radiated RFI
Fast Transient
Oscillatory
44
Test
Ripple on DC
Power Supply
Damped
Oscillatory Wave
Voltage Dips
and Interrupts
Dielectric Strength
HV Impulse
Description
ESD
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Description
DC Power Ports
Slow Damped
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Test Levels
Severity Levels
10%
2.5 kV Common
Mode on Power
and Signal
1.0 kV Differential
Mode on Power
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Fail-Safe
Relay Output)
2 kV
2 kV
5 kV (Fail-Safe
Relay Output)
5 kV
Test Levels
±2 kV
±4 kV
±8 kV
±4 kV
±8 kV
±15 kV
35 V/m
4 kV @ 2.5 kHz
4 kV
4 kV
4 kV
2.5 kV Common Mode @ 1 MHz
2.5 kV Common
1 kV differential mode @ 1 MHz
2.5 kV Common
Installation Manual, 11/2022, C79000-G8976-1040-20
3
3
 
 
 
 
 
 
 
RUGGEDCOM RSG2100

Advertisement

Table of Contents
loading

Table of Contents