Removing A Gbic Optical Port - Siemens RUGGEDCOM RSG2200 Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2200:
Table of Contents

Advertisement

Chapter 4
Communication Ports
IMPORTANT!
Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2200.
1.
Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic discharges
(ESD). This can be accomplished by wearing an ESD-preventive wrist strap connected to either the chassis
ground connector or a bare metal surface on the router/switch.
2.
Remove the dust cover from the port opening in the module.
3.
Remove the port from its packaging.
CAUTION!
Mechanical hazard – risk of component damage. GBIC optical ports are designed to insert in only
one orientation. Do not force the port into the module.
4.
Remove the dust plug from the socket and store for future use.
5.
Squeeze the latches on either side of the port and insert the port into the socket.
Figure 21: Installing a GBIC Optical Port
1. GBIC Optical Port Module    2. Socket    3. Locking Latch
6.
Release the latches and make sure the port is locked in place.
IMPORTANT!
Only remove the dust plug when ready to connect a cable to the GBIC optical port.
7.
Remove the dust cover from the port and store for future use.
8.
Remove the dust cap from the cable and immediately connect it to the port.
9.
Connect the cable to a network and observe the LED associated with the port. For more information about the
LED, refer to
Chapter 4, Communication
Section 4.4.2

Removing a GBIC Optical Port

To remove an GBIC optical port, do the following: