O P E R A T O R ' S
The lower plate of the brew mechanism
has been lowered or removed.
Switch off the machine.
Open the door, replace and close the
lower clamp plate.
Take care when handling the lower
plate as it has sharp cutting edges!
Switch on the machine.
or
An internal error has occurred.
Switch off the machine. After a delay of
5 seconds switch on again, this should
reset the machine.
If the problem recurs, call a Technical
Service Representative.
H A N D B O O K
or
The machine has been trying to heat the
water for 20 minutes without success.
This suggests that the over-temperature
reset button has tripped, or the element
has failed.
Press the RED over-temperature reset
button situated on the top right hand side
panel, inside the main front door.
PRESS THE RESET BUTTON.
If the problem recurs after a further 20
minutes, SWITCH OFF THE
MACHINE, and call a Technical
Service Representative.