Page 1
Man Pt No 705423 Rev 20170308 N E W C O E N T E R P R I S E S INSTALLATION, OPERATION, AND SERVICE MANUAL FOR NK SERIES AUTOMATIC & FAUCET BREWERS Weight Model Warmers Width Length Height...
PLUMBER'S INSTALLATION INSTRUCTIONS CAUTION: Power to brewer must be OFF before proceeding with plumbing installation. Attach flow/strainer assembly to back of brewer. Strainer inlet will point down. Flush water line before installing brewer. Brewer should be connected to COLD WATER LINE for best operation. Water pressure should be at least 20 lbs.
Tea Brewer Installation continued... Set timer to 180 seconds (3 minutes). Start brew cycle by turning lighted rocker switch on and pressing brew start switch. Tea urn should fill with one brew cycle. If not, adjust timer until desired level in tea urn is achieved (3 gallons). Open needle valve by turning counter clockwise 3 to 4 full revolutions.
Page 4
705371 NK stove top, 1 station cover 705201* Switch plate, NKLP3, -4, -5 705370 NK stove top, 2 station cover 100058 Nameplate, NEWCO 110624 Cover, pour in 100145-10 Faucet, Tomlinson with flare 110623 Grid, pour in 100085 Rocker switch, ON/OFF, lighted...
NEWCO’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall Newco be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of...
TROUBLE SHOOTING GUIDE SYMPTOM POSSIBLE CAUSE WHAT TO CHECK REMEDY CAN'T START BREW CYCLE 1. No water. 1. Incoming water lines & water shut 1. Be sure water shut off is open. off valve. 2. No power. 2. Fuse or circuit breaker. 2.
Page 8
TROUBLE SHOOTING GUIDE SYMPTOM POSSIBLE CAUSE WHAT TO CHECK REMEDY 1. Not siphoning properly. 1. Refer to "DRIPPING", Step 1. 1. Refer to "DRIPPING", Step 1. IRREGULAR YIELD 2. Timer. 2. Timer consistency. Time several 2. If times are irregular, replace timer. brew cycles.
TROUBLE SHOOTING GUIDE CONTINUED SYMPTOM POSSIBLE CAUSE WHAT TO CHECK REMEDY 1. Tank lid gasket. 1. Nicks or cuts in the gasket. 1. Replace gasket. CONDENSATION ON INSIDE OF CABINET 2. Sprayhead tube ass'y. 2. Tightness of ass'y to lid. 2.
Page 10
WARMER ELEMENT Remove retaining screws from warmer plate. Lift plate and disconnect leads. Remove nuts and washers holding retaining plate and warmer element to plate. Installation is reverse of removal. HOT WATER COIL Remove the 8 tank lid retaining nuts. Lift tank lid assembly out of tank. Remove the 2 compression nuts from top of hot water coil and remove old coil.
WIRING DIAGRAMS NK Automatic/Automatic With Faucet - 120 or 120/240 V; 208 V NK Automatic/Automatic With Faucet - 240 or 208 V Newco Enterprises, Inc. * 1735 South River Rd. * P.O. Box 852 * St. Charles, MO 63302...