Test 3: Measure Ac Voltage Output Of Each Stator Leg At Charging Rpm; Regulator / Rectifier (Dynamix); Regulator Replacement - Polaris RZR XP Service Manual

2018-2019
Table of Contents

Advertisement

ELECTRICAL
Any measurement other than Infinity (open) will indicate
a failed or shorted stator leg.
TEST 3: MEASURE AC VOLTAGE OUTPUT OF
EACH STATOR LEG AT CHARGING RPM
1. Set the selector dial to measure AC Voltage.
2. Start the engine and let it idle.
3. While holding the engine at a specified RPM,
separately measure the voltage across each 'leg' of
the stator by connecting the meter leads to the wires
leading from the alternator (Y1 to Y2, Y1 to Y3, Y2 to
Y3).
4. Refer to the following table for approximate AC
Voltage readings according to RPM. Test each leg at
the specified RPM in the table.
If one or more of the stator leg output AC voltage varies
significantly from the specified value, the stator may
need to be replaced.
RPM READING
1300
3000
5000
12.22
NOTE
NOTE
AC VOLTAGE (VAC)
READING
24 VAC ± 25%
50 VAC ± 25%
82 VAC ± 25%

REGULATOR / RECTIFIER (DYNAMIX)

The dual regulator / rectifier assemblies are located
behind the front fascia grill in front of the radiator.
If the regulator / rectifier case temperature exceeds 230°
F or 110° C, the unit will turn itself off to cool down. The
unit will turn on again after it has cooled down to at least
212° F or 100° C. If it turns off, verify the cooling fins are
clean, free from debris and that adequate airflow is
present.

REGULATOR REPLACEMENT

1. Remove the seat and disconnect the negative battery
terminal.
2. Remove the front fascia grill cover by pulling down on
the two tabs to release it.
3. Disconnect the two wiring harnesses
regulator(s) being removed.
9929419 R02 - 2018-2019 RZR XP / XP 4 Turbo S Service Manual
q
going to the
© Copyright Polaris Industries Inc.