Installation
76
Water connection
A water connection pressure of a minimum of 100 kPa (1 bar) and a
maximum of 1000 kPa (1 bar) is required to guarantee problem-free
operation.
1
2
3
4
5
6
a
Cold water for liquid dispensing
b
Hard water (cold water)
c
Casing side
d
Casing lid
e
Cold water
f
Hot water
The connection to the supply line must be made via a water shut-
off valve. This installation may only be carried out by an authorised
installation technician in accordance with local and national regula-
tions and regulations of the local water supplier.
The machine must be connected to the water supply using the water
inlet hoses provided.
The hot water supply must not exceed a maximum temperature of
70 °C.
Hoses must be replaced with hoses tested for a burst pressure of at
least 7000 kPa (70 bar) overpressure. The hoses must be suitable for
a water temperature of at least 90 °C. The same requirements also
apply to associated connection fittings. Miele original spare parts
meet these requirements.