Installing the Metal Grease Filter
 Insert back the metal grease filter and lock it in place, at the same time take hold of the
grease filter from underneath using your other hand to insert into the grease filter holder,
make sure the grease filter is positioned correctly.
 If the metal grease filter has not been inserted correctly, the buzzer (fast beat) will sound,
and the glass panel will not descend until the metal grease filter is properly inserted, press
the grease filter locking clip and reinsert it again. When the metal grease filter is correctly
inserted, the buzzer will buzz again for 10 seconds before the glass panel slides to descend
until it is fully closed.
Cleaning the Appliance Body
Clean the extractor hood using warm detergent solution and a soft damp cloth. After
cleaning, dry it using a lint free cloth.
Avoid using corrosive or abrasive products that could damage the surface.
Do not clean the controls with a wet cloth as this may risk damage due to ingress of humility
into the electronic circuitry
Oil Collector Cup
Cleaning the Oil Collector Cup
LED Lights
Defective LED lights can only be replaced by the manufacturer, their customer service or their
authorized after sales service agents only.
(Fig. 3 & Fig. 3. 1)
 Hold both sides of the oil collector in a
horizontal position and slowly slide the oil
collector from the unit. As oil may be present
in the oil collector hold the oil collector flat
when removing it out of the housing. (Fig. 3
& Fig. 3. 1)
 Clean the oil collector by using warm
Fig.3
detergent solution. Leave it to dry before
refitting
 Reverse the procedure when fitting back.
 If the oil level is seen to filled up to two thirds
of the oil collector, you are requested to
dispose the oil to avoid any overflowing
Fig.3.1