8340/41
B
CALIBRATION CONSTANTS
SERIAL NUMBER;
0000
834041 BREV
11
MAR 88
1. DMELLTIME
50
11
34.
AT90
SLOPE
-10
11
67.
AT60
SLP
20G2
10
2.YTMBXDLY2
74
11
35.
LEV
DAC
OFF; SYS
-2
11
68.
AT70
SLP
20G2
13
3.YTMBXDLY3
69
II
36.
LEV
DAC
GAIN;
SYS
-27
II
69.
AT80 SLP 20G2
15
4.
YTMBXDLY4
100
11
37.
ADC
OFF SYS
-
-1
11
70.
AT90
SLP
20G2
18
S. YTMDLY1
80
II
38.
ADC
GAIN
SYS
-3
II
71.
YTM
OFFSET
1
1055
6.
YTMDLY2
101
11
3S.
ADC
GAIN
LO
-40
11
72.
YTM
OFFSET
2
1108
7.
YTMDLY3
100
11
40.
ADC
GAIN HI
-40
11
73.
YTM
OFFSET
3
902
8.
YTMDLY4
100
11
41.
MAX
SWEEP RATE
600
II
74.
YTM
OFFSET
4
1024
9.
YTMGAIN1
1084
II
42.
ADC
OFFSET
3
II
75.
YTM SGL BD
RT
25
10.
YTM
GAIN
2
964
11
43.
AM
OFFSET
2
11
76.
YTM
MLT
BD
RT
1000
11. YTMGAIN3
1151
II
44.
LVLDACOFF; INT
-6
II
77.
YTM BX RTA
-25
12. YTMGAIN4
1024
II
45.
LVL
DAC OFF
;
EXT
0
II
78.
YTM BX RTB
25
13.
LO
SLOPE
49
11
46.
LVL
DAC
GAIN;
LO
11
II
79.
01 MODEL
5
14.
HI
SLOPE
117
II
47.
LVL
DAC
GAIN;
HI
12
11
80.
YTM TEMP COMP
-17
15.
9G2SLOPE
80
II
48.
LVL
DAC
GAIN
;
EXT
-23
II
81.
LOCKUORD
0
16.
20G2
SLOPE
129
11
49.
PMR
SUP
GAIN
4
11
82.
LOCKUORD ENABLE
0
17.
AT10 OFFSET
-5
11
50.
YTM BX
GAIN
1
0
11
•83.
ANALY2ER
SMP
RATE
125
18.
AT20 OFFSET
-7
II
51.
YTMBXGAIN2
0
11
84.
unused
0
19.
AT30 OFFSET
-5
II
52.
YTM
BX
GAIN
3
0
II
85.
unused
0
20.
AT40 OFFSET
-9
II
53.
YTM BX
GAIN
4
0
II
86.
unused
0
21.
AT50 OFFSET
-10
11 •
54.
STOP
LIMIT
2650
11
87.
unused
0
22.
AT60 OFFSET
-11
1C 55.
STARTLIM1T
1
II
88.
unused
0
23.
AT70 OFFSET
-14
II
56.
PRESET OPTION
O
II
89.
unused
0
24.
AT80
OFFSET
-20
II
57.
HPIBADDRESS
19
II
90.
unused
0
25.
AT90 OFFSET
-23
II
58.
RETRACE DWELL
O
II
91.
unused
'
0
26.
AT10
SLOPE
-1
II
59.
ATTENCONFIG
9716
II
92.
unused
0
27.
AT20
SLOPE
-2
II
60.
CONFIGURATION
513
11
93.
unused
0
28.
AT30 SLOPE
-3
11
61. SERIAL'
378
11
94.
unused
0
29.
AT40
SLOPE
-5
11
62.
AT10
SLP
20GZ
4
II
95.
unused
0
30.
AT50 SLOPE
-5
II
63.
AT20
SLP
20G2
5
II
96.
unused
0
31.
AT60 SLOPE
-7
11
64.
AT30
SLP
20G2
5
11
97.
unused
0
32.
AT70 5LOPE
-8
11
65.
AT40
SLP
20G2
8
11
98.
MODEL'
5
33.
AT80 SLOPE
-9
11
66.
AT50
SLP
20G2
9
11 •
99.
CHECKSUM
24097*
Procedure for
manually entering calibration data into the
SOURCE:
1.
Push the following sequence of KEYS:
[INSTR PRESET] [SHIFT] [MHz] [1] [2] [Hz] [SHIFT] [KHz] [2] [2] [Hz]
2.
Note the
Entry Display will indicate the Calibration Constant
number and value.
3.
Enter via the KEY
BOARD
or DATA
KNOB the
correct value
for
the
first
Calibration Constant indicated
in
the
display.
«
Terminate KEYBOARD entries with the Hz key
»
4.
Go
to
the next Calibration Constant by pushing the UP step key.
The next
constant can then be entered- Do no
enter the
"CHECKSUM"
Constant (This
is
computed automatically)
5.
The Step
Keys can be used
to
move from one Calibration Constant to another to either check them
or
to correc
them.
6.
After
all
entries have been made, check that
all
numbers are correct by using the step keys to review and
verify
them
7.
Allow instrument to warm up for 1/2 hour and
make
sure that nothing
is
connected to the Stop Sweep connecto
on the rear panel. Press
[SHIFT PEAK]
to
perform
an Automatic Tracking Calibration.
This
step may
modify
the
"YTM
GAIN n"
&
"YTM
BX
GAIN
n" constants.
8.
The CALIBRATION data
should be permanently stored
in
the Non Volatile Protected
Memory
by pushing
the
following key
sequence [SHIFT]
[MHz]
[1] [4] [Hz] [SHIFT] [KHz] [5] [3] [4] [9] [Hz] [INSTR PRESET]
"Will
vary depending on
individual
instrument
i
t
t
/
r
f
3
Figure A-3.
Sample Calibration Constants Printed Copy (Found Inside Instrument)
A-24
Assembly-Level Service Calibration constants
Change
7
HP 8340B/41B