Samsung EHS AE050RXYDEG/EU Manual page 141

Table of Contents

Advertisement

8. System configuration
4) Periodical Disinfection heating of water tank (#304*)
Main Menu
Sub Menu Function
(FSV)
DHW
Disinfection
FSV 30**
#3044
5) Forced DHW operation (#305*)
Main Menu
Sub Menu Function
(FSV)
DHW
Forced DHW
FSV 30**
Operation
• Forced DHW mode shall be working depending on timer setting.
• #3051 : Set whether to use a timer for forced DHW function.
• #3052 : Set time for forced DHW operation.
Installer reference guide / Mono tank integrated type
Description
Application
Interval
Start Time
Target Temp.
Duration
Max time
#3042
#3045
#3043
Description
Timer OFF Function
Time Duration
FSV
Step
Unit
3041
-
-
3042
1
day
3043
1
o'clock
3044
5
˚C
3045
5
min
3046
1
hour
#3043 : Start time for disinfection (0~24hr)
#3044 : Target temp.for disinfection
#3045 : Time duration which satisfy the target temp. for
disinfection
FSV
Step
Unit
3051
-
-
3052
1
(x10)min
Default
Min.
Max.
1 (On)
0 (Off)
1
Fri (5)
Sun (0)
All (7)
23
0
23
70
40
70
10
5
60
8
1
24
Default
Min.
Max.
0 (No)
0
1 (Yes)
6
3
30
140