Samsung EHS AE050RXYDEG/EU Manual page 139

Table of Contents

Advertisement

8. System configuration
2) DHW heating mode timer (#3024-3032)
Main Menu
Sub Menu Function
(FSV)
DHW
Heat Pump
FSV 30**
• #3024 ~ #3026 : Time variation control between DHW and space heating mode
• #3025, #3032 : Time variation control of heat pump and booster heater
• Mode timer manage the operation terms when there are simultaneous requests of space heating/cooling and DHW.
– FSV #3024 (minimum Space heating operating time, default 5 min., Range 1 ~ 20 min.), #3025 (maximum DHW
time, default 30 min., Range 5 ~ 95 min.), #3026 (maximum space heating operation time, default 3 hour,
Range 0.5 ~ 10 hour)
– Maximum operation time is applied only when both DHW and space heating request operation. DHW or space
heating operates continuously until reaching at target temperature without time limitation in the single operation.
• Time variation control of DHW and Space heating mode
Space heating request
DHW request
DHW operation
Space heating operation
• Time variation control of Heat Pump and Booster heater
Heating request
DHW request
H/P Operation
Booster Operation
Installer reference guide / Mono tank integrated type
Description
Min. Space heating operation time 3024
Max. DHW operation time
Max. Space heating operation time 3026
1
0
1
0
1
#3024
0
#3025
#3026
1
0
1
0
#3025
1
0
1
0
#3032
FSV
Step
Unit
1
min
3025
5
min
0.5
hour
#3024 : Minimum time for Space heating operation
#3025 : Maximum time for DHW operation
#3026 : Time for Space heating operation after DHW operation
t
#3025 : Maximum time for DHW operation
#3032 : Delay time for activation of Booster heater
t
Default
Min.
Max.
5
1
20
30
5
95
3
0.5
10
138

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents