7. Electrical installation
FSV setting table
• When changing the backup heater for a different capacity, it is required to also change the FSV settings for the energy
metering function.
1 To accurately indicate the energy consumption, the capacity of the backup heater must be set using FSV #3081.
[Default setting : 2(kW) / MHC-400FE : 4(kW) / MHC-600FE : 6(kW)]
2 For using the various additional functions of the Wired Remote Controller, press the and
for more than 3 seconds.
– The password entry screen appears.
3 Enter the password, 0202, and then press the
– The settings screen for installation/service mode appears.
4 See the list of additional functions for the Wired Remote Controller on the next page, and then select the desired
menu.
– After entering the setting screen, the current setting appears.
– Refer to the chart for data setting.
– Using the
/
buttons, change the settings and press the button to move to the next setting.
– Press the
button to save the new setting.
– Press the
button to move to the Home screen.
NOTE
• While setting the data, press the
at a pop-up screen..
Main Menu
(FSV)
DHW
FSV 30**
Installer reference guide / Mono tank integrated type
Menu
Addition
Energy
Function
metering
button.
button to move to the Home screen after checking the saving status
Function
Item
Step
Backup
Heater
1
1step capacity
buttons at the same time
Setting Standard
FSV
Unit
Default
kW
3081
2
Min.
Max.
1