■ D-3.9.2 Auxiliary circuits oil filter

To change the hydraulic oil filter cartridge of the service
circuits, proceed as follows:
1
Stop the machine on a level ground and engage the
parking brake.
2
Remove the inspection hatch
oil filter fitted inside the tank.
3
Check the tank is clean, then fit a new filtering
element and refit the inspection hatch.
4
Check the oil level within the tank. Add new oil, if
necessary.
SERVICE INTERVAL
Running-in ____________________________ None
Ordinary __________________ Every
Handler with telescopic boom GTH-2306
MAINTENANCE
and unscrew the
500
hours