5.9.5

Stationary/rotating measurement

Overview
Motor identification (MotID) provides a means of determining motor data, for example, of third-
party motors. To improve control properties of the motor, the MotID should be performed. The
main motor identification components are the stationary and rotating measurements.
Adjustment
range
Measurement
type
Configuration
Status
Measurement
result
Figure 5-16
NOTICE
Damage to the device as a result of incorrectly selected rated or maximum current values
Incorrect rated or maximum current data can destroy the motor!
• Check that the current values that have been entered are correct.
Note
Loss of the determined motor data during restart
If a power on or a warm restart is performed when the motor data identification is selected, then
the motor data identification request is lost. A requested motor data identification must be
reselected manually after powering up.
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2
Explanation
For selecting the measurement type (for experts)
For entering configuration data for the selected measurement type (for experts)
Indicates measurement progress
Displays the measurement results of the MotID. The measurement results can be cor‐
rected or accepted.
Example: stationary/rotating measurement deactivated
Commissioning
5.9 Commissioning a drive
257