Advertisement

Commissioning
5.3 Creating a project offline
Requirements
• A SINAMICS S120 Control Unit has been inserted in the device configuration.
• No Communication Board CBE20 is contained in the device configuration.
TB30 and CBE20 cannot be created simultaneously in the device configuration.
Note
A TB30 Terminal Board and a CBE20 Communication Board cannot be created simultaneously
in the device configuration.
Procedure
To insert a TB30 into the device configuration, proceed as follows:
1. Open "Additional system components > Terminal Boards" in the hardware catalog.
The "TB30 Terminal Board" entry is displayed.
2. Select the TB30 Terminal Board in the device overview.
3. Drag the Terminal Board to the device view.
Result
The TB30 is inserted in the drive and does not have to be specified in any more detail.
5.3.9.5

Insert Voltage Sensing Module VSM10

Overview
Voltage Sensing Modules (VSM) can be used for the following different drive objects:
• Infeed unit
– Is used for voltage measurement (e.g. for the "mains transformer" function).
– The VSM10 allows an exact recording of the line voltage curve and supports the fault-free
• Motor Modules, type vector
– Required for the functions "synchronize" and "flying restart".
Requirements
• A SINAMICS S120 Control Unit has been inserted in the device configuration.
• An infeed unit is inserted into the device configuration.
OR
• A Motor Module, type vector is available.
150
operation of the Line Modules in unfavorable network conditions.
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2