Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine's electrical characteristics.
OR
• If you repair or replace any electrical components.
Mode
Low Idle
High Idle
Output Control
Maximum
Output Control
Maximum
Output Control
Maximum
230 Volt Receptacle
Open Circuit
Load Volts
Voltage
246 - 264
216 - 250
Slip Ring Volts
28.0 - 46.0 VDC
1
OUTPUT CONTROL switch set at MAXIMUM (position 10).
2
Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.
All manuals and user guides at all-guides.com
TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

ENGINE OUTPUT
No Load RPM
2150-2250
3700-3750
WELDER DC OUTPUT
Range Switch
Open Circuit
Maximum
65 - 72
WELDER AC OUTPUT
Range Switch
Open Circuit
Maximum
73 - 80
WELDER CV OUTPUT
Range Switch
Open Circuit
Wire Feed CV
29 - 33
AUXILIARY POWER RECEPTACLE OUTPUT
Load Amps
34 - 41.5
FIELD AMPS AND VOLTS
RANGER® 10,000 & RANGER® 10,000 PLUS
1
Load Volts
Volts
21 - 26.5
1
Load Volts
Volts
25 - 32
1
Load Volts
Volts
19 - 22
115 Volt Receptacle
Open Circuit
Voltage
123- 132
Field Amps
6.5 - 7.5 VDC
Load RPM
NA
3100-3600
Load Amps
205 - 240
Load Amps
225 - 275
Load Amps
200 - 220
1
2
Load Volts
Load Amps
114 - 126
35 - 42