Retest After Repair - Lincoln Electric SAE-300 HE Service Manual

Hide thumbs Also See for SAE-300 HE:
Table of Contents

Advertisement

LINCOLN ELECTRIC
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any part which could affect the
machine's electrical characteristics.
OR
• If you repair or replace any electrical components.
HIGH IDLE
LOW IDLE
WELDING PROCESS
DC CONSTANT CURRENT
VOLTS
120
240

RETEST AFTER REPAIR

IDLE RPM
RATED OUTPUT @ 104° F (40° C) – WELDER
WELDING OUTPUT
CURRENT/VOLTAGE/DUTY
CYCLE
250A / 30V / 100%
300A / 32V / 60%
RATED OUTPUT @ 104° F (40° C) - GENERATOR
AUXILIARY POWER SINGLE PHASE 60 HZ AC
ENGINE OUTPUT
1800
1440
OUTPUT RANGE AMPS
30A TO 300A
AMPS
26 AMPS
13 AMPS
SAE-300® HE Service Manual
FULL LOAD RPM
1800
N/A
MAX. WELD OCV @
FULL LOAD RPM
90 VOLTS
POWER
3,000 WATTS
3,000 WATTS
79