Fuel Conversion; Conversion Instructions - Vermont Castings VWDVP70NTSC Installation And Operating Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

VWDV70 Series Gas Fireplace
NOTE: This Kit Must be Installed by a Qualifi ed Service Agency
This conversion kit shall be installed by a quali-
fi ed service agency in accordance with the man-
ufacturer's instructions and all applicable code
and requirements of the authority having juris-
diction. If the information in these instructions
is not followed exactly, a fi re, explosion or pro-
duction of carbon monoxide may result causing
property damage, personal injury or loss of life.
The qualifi ed service agency is responsible for
the proper installation of this kit. The installa-
tion is not proper and complete until operation
of the converted appliance is checked as speci-
fi ed in the manufacturer's instructions supplied
with the kit.
LOGS MAY BE HOT TO THE TOUCH. HANDLE
THE LOGS WITH GLOVES AND PLACE THEM
ON A NONCOMBUSTIBLE SURFACE WHEN
THEY HAVE BEEN REMOVED FROM THE IN-
SERT.
Before installing conversion kit...
Disconnect electrical power.
Shut off gas supply.
Allow unit to cool.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors
and liquids in the vicinity of this or any other appliance.
The procedure for converting from one gas to another
is the same regardless of the initial gas used, except
where noted. The only variation is in the orifi ce sizes
and component part numbers. Your authorized service
provider will ensure the correct parts are used.
The parts needed to convert from natural gas to LP
are provided with the fi replace. The parts to convert
from LP to natural gas must be purchased from an
authorized dealer. Refer to Page 54.
Conversion parts included:
Burner orifi ce (refer to Table 1)
Pilot orifi ce
Gas valve regulator
Conversion rating plate label
Conversion cap
Venturi air shutter (for conversion to Natural gas only)
Tools required: Torx T20 Driver (2
recommended) or Slotted Screwdriver, 5/8", 11/16", 3/4"
and 7/8" Combination Wrenches, Phillips Screwdriver
46
" minimum length
1
2

CONVERSION INSTRUCTIONS

1. Using the hand tool provided with the unit, remove
the glass door by rotating the three (3) cams to re-
lease the door from its locked position. Tilt top of
glass frame away from unit and lift up and away.
CAUTION: An assistant may be necessary to help re-
move glass frame.
2. Carefully remove the stones and glass on the left
front 2/3 of the burner to expose the left lens placed
in front of the burner.
3. Remove the two (2) left lenses placed in front of the
burner.
4. Remove the right side panel and place on protected
surface to prevent damage.
5. To gain access to the gas valve and control board,
remove the access plate located on the right side of
the unit by removing the screws that secure the plate
to the side.
6. Using the Torx T20 driver or slotted screwdriver, re-
move and discard the regulator and rubber gasket in
the face of the valve.
Figure 74
7. Install the new regulator with rubber gasket from the
conversion kit. Make sure the gasket is seated prop-
erly.
8. Remove control board and A/C module assembly. It is
attached with velcro fasteners to the wall of the enclo-
sure behind the access plate removed earlier.
9. Separate the A/C module from the control board by
removing screw. Figure 75

FUEL CONVERSION

20306745

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vwdv70ntscsb

Table of Contents