Vermont Castings VWDVP70NTSC Installation And Operating Instructions Manual page 43

Direct vent gas fireplace
Table of Contents

Advertisement

TOUCH SCREEN REMOTE CONTROL OPERATION
NOTE: There will a 10 second delay for the fl ame adjust-
ment when the fi replace is turned on.
1. When Set Temp. is 3° F or
higher than Room Temp.,
fl ame height will be on High.
2. When Set Temp. is 2° F high-
er than Room Temp., fl ame
height will be on Medium.
3. When Set Temp. is 1° F high-
er than Room Temp., fl ame
height will be on Low.
4. When Set Temp. is equal to
Room Temp., fl ame height
does not change (stays on
low).
5. When Set Temp. is lower
than Room Temp., the fi replace will be shut off.
6. When Set Temp. is 1° F higher than Room Temp.,
again the fl ame height will be on Low.
7. the fan speed follows the fl ame height, if the fan is
turned on.
To exit Smart Mode
and shut off the fi replace:
®
a. push and hold the THERMO buttons for 3 sec-
onds, Or
b. press the OFF button, Or
c. slide down on the arrow buttons.
To shut off the Smart Mode
thermostat mode, press and hold the THERMO button
and the ON/UP button at the same time for 3 seconds
again.
Blower Speed Control (not used with VWDV70)
Figure 69
NOTE: Blower will only work with fl ame on.
The blower speed control function is used to adjust the
speed of the blower connected to the Signature Com-
mand System. There are four speed levels, Off, Low, Me-
dium, High.
1. Press the FAN button to enter
the blower speed control mode.
The fan icon will start fl ashing.
2. Press the ON/up and OFF/down
button to increase/decrease the
blower speed.
3. Press the fan button again to
confi rm the speed setting. If the
fi replace is on, the blower speed
will take effect right away; if the
fi replace is off, the receiver will
remember this setting and the
blower is still off (see blower On
Delay and Off Delay in the next
section).
20306745
Figure 68
option and return to regular
®
Figure 69
4. After the signal is sent, the ON/up and OFF/down but-
tons become fl ame height controller again.
5. When the fan button is fl ashing, slide up and down on
the arrow buttons will turn the blower speed to High
or Off directly without pressing the fan button again to
confi rm.
Smart
Mode
6. If the blower is turned on using the FAN button, the
Icon
blower speed will adjust automatically when using
Smart Mode (See Smart Mode section).
Blower On Delay Time and Off Delay Time Setup
(not used with VWDV70)
Figure 70
1. Hold the FAN button for 3
seconds until two numbers
appear on the LCD screen.
The left number is blower On
Delay and the right number is
blower Off Delay Time.
2. When the fi rst number is fl ash-
ing, use the ON/up button to
set the desired On Delay Time
from 0 to 15 min.
3. Press the OFF/down button
to jump to the Off Delay Time
setup.
4. When the second number is
fl ashing, use the ON/up button
again to set the desired Off Delay Time from 0 to 15
min.
5. Press the OFF/down button again to fi nish the setup
and the new settings will be transmitted to the receiver.
6. The default settings are 5 minutes for the On Delay
Time and 8 minutes for the Off Delay Time, as shown.
Light Brightness Control
Figure 71
The light brightness control function is used to adjust the
brightness of the light bulbs connected to the AC module
on the Signature Command System. There are four light
brightness levels defi ned: Off, Low,
Medium, High
1. Press the LIGHT button to en-
ter the light brightness control
mode. The LIGHT icon will start
fl ashing.
2. Press the On/up and OFF/down
buttons to increase/decrease
the light brightness (Off-Low-
Medium-High).
3. Press the light button again to
confi rm the setting. The new
setting will be transmitted to the
receiver.
VWDV70 Series Gas Fireplace
Figure 70
Figure 71
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vwdv70ntscsb

Table of Contents