Station Connections
Pair PIN #
1
26
1
2
27
2
3
28
3
4
29
4
5
30
5
6
31
6
7
32
7
8
33
8
9
34
9
10
35
10
11
36
11
12
37
12
Installing the DTRU or DTRU4 Module
DTRU to SLIB
1. Unpack the DTRU module from its antistatic conductive bag.
2. Locate the CON1 and CON2 connectors on the DTRU module.
3. Locate the CN1 and CN2 connectors on the SLIB.
4. Position the DTRU module so that its CON2 aligns with the CN1 connector and its CON1
aligns with the CN2 connector on the SLIB.
5. Push the DTRU module onto these connectors to seat it securely.
Table 3-20: SLIBE & SLIBC Wiring
Color
Description
WH/BL
Ring 1
BL/WH
Tip 1
WH/OR
Ring 2
OR/WH
Tip 2
WH/GN
Ring 3
GN/WH
Tip 3
WH/BN
Ring 4
BN/WH
Tip 4
WH/SL
Ring 5
SL/WH
Tip 5
RD/BL
Ring 6
BL/RD
Tip 6
RD/OR
Ring 7
OR/RD
Tip 7
RD/GN
Ring 8
GN/RD
Tip 8
RD/BN
Ring 9
BN/RD
Tip 9
RD/SL
Ring 10
SL/RD
Tip 10
BK/BL
Ring 11
BL/BK
Tip 11
BK/OR
Ring 12
OR/BK
Tip 12
Pair PIN #
Color
13
38
BK/GN
13
GN/BK
14
39
BK/BN
14
BN/BK
15
40
BK/SL
15
SL/BK
16
41
YL/BL
16
BL/YL
17
42
YL/OR
17
OR/YL
18
43
YL/GN
18
GN/YL
19
44
YL/BN
19
BN/YL
20
45
YL/SL
20
SL/YL
21
46
VI/BL
21
BL/VI
22
47
VI/OR
22
OR/VI
23
48
VI/GN
23
GN/VI
24
49
VI/BN
24
BN/VI
25
50
VI/SL
25
SL/VI
Chapter 3 - System Installation
Description
3-51