Vodavi STARPLUS Triad XTS Installation Manual page 75

Table of Contents

Advertisement

CO/PBX Connections
(3) T1IBs and (2) BRIBs
T1IB1
SW3 On
The clock OUT cable from T1IB1 should be connected to the clock IN cable of the T1IB2 and
the clock OUT cable from T1IB2 should be connected to the clock IN cable of T1IB3. SW3 of
T1IB1 should be in the ON position, and SW3 of T1IB2 and T1IB3 should be in the OFF
position. The two BRIBs are not connected with clock control cables and SW2 of the BRIB
cards are placed in the OFF position.
Clock Chain Using T1 / PRIB / BRIB
The following four illustrations are clock chain examples that apply to PRIB or T1 use. Arrows
on the illustrations represent data flow. The BRIB clock chain is similar, in that you always
connect:
IN of LMU1 to OUT of the BRIB closest to the LMU1
OUT of a BRIB in Cabinet 1 to the IN of next closest BRIB
IN of LMU2 to OUT of the BRIB closest to the LMU2
IN from a BRIB in Cabinets 1 or 2 to the next closest BRIB
IN from the last BRIB to OUT of LMU2.
The callout of
Switch to either PRI/BRI or T1, is applicable to all examples.
The expanded view callout at the top right of
connectors on LMU2 when there is a T1 or ISDN card in the associated Cabinet. The expanded
view callout at the middle right of the same illustration shows the connection required for
Cabinets 1 or 2 when the Cabinet(s) do not have T1 or ISDN cards in use.
T1IB2
T1IB3
SW3 Off
SW3 Off Switch 4, SW2 Off Switch 4, SW2 Off
Figure 3-24: Case 1 of Clock
BRIB1
Chain, that pertains to setting the Clock Source
Figure 3-26: Case 3 of Clock Chain
Chapter 3 - System Installation
BRIB2
shows the
3-41