Wiring The Fault Alarm Contact - Planet IGUP-805AT Quick Installation Manual

Industrial 1-port 100/1000x sfp to 1-port 10/100/1000t 802.3bt poe++ media converter
Table of Contents

Advertisement

2. Tighten the wire-clamp screws for preventing the wires from loosening.
1. The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
2. The DC power input range is 12-54V DC.
Note
PWR1 and PWR2 must provide exactly the same DC voltage for
power load balance while operating with dual power input.

2.5 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block connector as
the picture shows below. When inserting the wires, the Industrial Ethernet
Extender will detect the fault status of the power failure and then form an
open circuit. The following illustration shows an application example for wiring
the fault alarm contacts.
Fault Alarm Contacts
8
1
2
Power 1
+
-
1
2
3
4
5
Alarm
Insert the wires into the fault alarm contacts
3
4
5
6
Alarm
Power 2
+
-
6
The Fault Alarm Contacts are energized
(CLOSE) for normal operation and will
OPEN when failure occurs