Siemens SCALANCE X101-1AUI Commissioning Manual
Siemens SCALANCE X101-1AUI Commissioning Manual

Siemens SCALANCE X101-1AUI Commissioning Manual

Simatic net industrial ethernet

Advertisement

Quick Links

SIMATIC NET
SIMATIC NET
Industrial Ethernet
SCALANCE X101-1AUI
Commissioning Manual
06/2006
A2B00051526A, Product Version 03
Introduction
Network Topologies
Product Characteristics
Installation and Maintenance
Notes on the CE Mark
References
Dimension Drawings
1
2
3
4
5
6
7

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X101-1AUI

  • Page 1 Introduction Network Topologies Product Characteristics SIMATIC NET Installation and Maintenance SIMATIC NET Industrial Ethernet Notes on the CE Mark SCALANCE X101-1AUI References Dimension Drawings Commissioning Manual 06/2006 A2B00051526A, Product Version 03...
  • Page 2: A2B00051526A, Product Version

    Siemens. This product can only function correctly and safely if it is transported, stored, set up and installed correctly, and operated and maintained as recommended.
  • Page 3: Table Of Contents

    SCALANCE X101-1AUI Unpacking and Checking..............3-2 SCALANCE X101-1AUI Product Characteristics..............3-3 SCALANCE X101-1AUI TP-RJ-45 Interface ................3-4 SCALANCE X101-1AUI AUI Interface ..................3-5 SCALANCE X101-1AUI Power Supply and Signaling Contact ..........3-7 SCALANCE X101-1AUI Button....................3-8 SCALANCE X101-1AUI LEDs ....................3-10 3.10 SCALANCE X101-1AUI Technical Specifications ..............
  • Page 4 15-pin SUB-D connector pinout ....................3-6 Figure 3-4 SCALANCE X101-1AUI power supply..................3-7 Figure 3-5 Connector pinout........................3-7 Figure 3-6 SCALANCE X101-1AUI signaling contact ................. 3-8 Figure 3-7 Connector pinout........................3-8 Figure 4-1 Installation on a DIN rail (35 mm) ....................4-2 Figure 4-2 Removing from a DIN rail (35 mm) ....................
  • Page 5: Introduction

    The “SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks” manual contains additional information on other SIMATIC NET products that you can operate along with SCALANCE X101-1AUI in an Industrial Ethernet network. Finding information To help you find the information you require more quickly, the manual includes not only the table of contents but also the following sections in the Appendix: •...
  • Page 6 The SCALANCE X-101-1AUI device enables the cost-effective installation of Industrial Ethernet bus and star structures with a media transition. Note It is not possible to use a SCALANCE X101-1AUI media converter in a redundant ring since it does not support the redundancy function. Note The requirements of EN61000-4-5, surge test on power supply lines, are met only when a Blitzductor VT AD 24V type no.
  • Page 7: Network Topologies

    Figure 2-1 Connection of a SCALANCE X108 to a 10Base5 segment via SCALANCE X101-1AUI Note SCALANCE X101-1AUI is a repeater. This has to be considered when connecting and designing the network topology (repeater rule). Industrial Ethernet Media Converters SCALANCE X-100 Series...
  • Page 9: Product Characteristics

    Product Characteristics Overview Table 3-1 Overview of the product characteristics Characteristics Device type X101-1AUI SIMATIC environment Diagnostics LED 24V DC Compact housing 40mm (securing collar, etc.) 2x 24 V DC Medium Attachment Unit (MAU) – supply with 12 V Signaling contact + on-site operation Diagnostics: Web, SNMP, PROFINET C-PLUG...
  • Page 10: Scalance X101-1Aui Components Supplied

    Do not use any parts that show evidence of damage! Warning If the SCALANCE X101-1AUI device is operated in ambient temperatures between 55°C- 60°C, the temperature of the device housing may be higher than 70°C. The subject unit must be located in a Restricted Access Location where access can only...
  • Page 11: Scalance X101-1Aui Product Characteristics

    Product Characteristics 3.4 SCALANCE X101-1AUI Product Characteristics SCALANCE X101-1AUI Product Characteristics Possible Attachments SCALANCE X101-1AUI features an RJ-45 jack and a 15-pin SUB D socket for the connection to AUI transceivers (MAU, Medium Attachment Unit). Figure 3-1 SCALANCE X101-1AUI Industrial Ethernet Media Converters SCALANCE X-100 Series...
  • Page 12: Scalance X101-1Aui Tp-Rj-45 Interface

    IE FC cables and IE FC RJ-45 plug 180. Note The transmission mode of Scalance X101-1AUI is set to 10 Mbps half duplex. Devices not supporting autonegotiation must be set to 10 Mbps / half duplex. Industrial Ethernet Media Converters SCALANCE X-100 Series...
  • Page 13: Scalance X101-1Aui Aui Interface

    Product Characteristics 3.6 SCALANCE X101-1AUI AUI Interface MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user.
  • Page 14: Figure 3-3 15-Pin Sub-D Connector Pinout

    Product Characteristics 3.6 SCALANCE X101-1AUI AUI Interface Connector pinout SUB-D socket (female) Figure 3-3 15-pin SUB-D connector pinout Pin number Pinout Shield Ground (M-GND) Pin 15 Pin 14 Ground (M-GND) Pin 13 Voltage Plus (12V +) Pin 12 DIN (Data In -)
  • Page 15: Scalance X101-1Aui Power Supply And Signaling Contact

    This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals. The power supply unit to supply SCALANCE X101-1AUI must comply with NEC Class 2 (voltage range 18-32 V, current requirement 470 mA).
  • Page 16: Scalance X101-1Aui Button

    Product Characteristics 3.8 SCALANCE X101-1AUI Button Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation. Figure 3-7 Connector pinout...
  • Page 17 Product Characteristics 3.8 SCALANCE X101-1AUI Button If an empty fault mask (P1 is not monitored) is set or is to be set, P1-LED flashes at a frequency of 2.5 Hz. Simultaneously with the fault mask, the monitoring of the connected power supply is set. The existence of the two power supply units is only monitored if both power supplies are connected during saving the fault mask.
  • Page 18: Scalance X101-1Aui Leds

    Meaning Not lit Stand-alone mode. The TL function (transparent link) is not possible. A direct cascade connection of two SCALANCE X101-1AUI media converters is not possible, thus no transparent link. Industrial Ethernet Media Converters SCALANCE X-100 Series 3-10 Commissioning Manual, 06/2006, A2B00051526A, Product Version 03...
  • Page 19: Scalance X101-1Aui Technical Specifications

    Product Characteristics 3.10 SCALANCE X101-1AUI Technical Specifications 3.10 SCALANCE X101-1AUI Technical Specifications Technical Specifications of SCALANCE X101-1AUI Ports Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 10 Mbps twisted pair (half duplex according to 10BaseT) Connection of further network components via...
  • Page 20 Product Characteristics 3.10 SCALANCE X101-1AUI Technical Specifications Permitted Environmental Conditions / EMC Operating temperature -10°C to +60°C Storage/transport temperature --40°C to +80°C Relative humidity in operation ‹ 95% (no condensation) Operating altitude 2000 m at max 56 °C ambient temperature 3000 m at max.
  • Page 21 6GK1 901-1BB10-2AE0 Note When a frame passes through the SCALANCE X101-1AUI media converter, it is typically delayed by approx. 40 µs by the "Cut Through" function of the internal switch. - At a network load of 100%, these times can increase system-dependently (max. 180 µs).
  • Page 23: Installation And Maintenance

    Installation and Maintenance Installation Types of Installation SCALANCE X101-1AUI can be installed in various ways: • Installation on a 35 mm DIN rail • Installation on a SIMATIC S7-300 DIN rail • Wall mounting Note When installing and operating the device, keep to the installation instructions and safety- related notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks /2/ manual.
  • Page 24: Installation On A Din Rail

    Installation and Maintenance 4.1 Installation 4.1.1 Installation on a DIN Rail Installation Install the media converter on a 35 mm DIN rail according to DIN EN 50022. 1. Place the upper catch of the device over the top of the rail and then push in the lower part of the device against the rail until it clips into place.
  • Page 25: Figure 4-2 Removing From A Din Rail (35 Mm)

    Installation and Maintenance 4.1 Installation Uninstalling To remove SCALANCE X101-1AUI from the rail: 1. First disconnect the TP cable and the AUI cables. Remove the terminal block for the power supply and the signaling contact. 2. Use a screwdriver to release the lower rail catch of the device and pull the lower part of the device away from the rail.
  • Page 26: Installation On A Din Rail

    Installation and Maintenance 4.1 Installation 4.1.2 Installation on a DIN Rail Installation on a SIMATIC S7-300 DIN rail 1. Place the upper guide at the top of the SCALANCE housing in the S7 standard rail. 2. Screw the media converter of the SCALANCE X-100 series to the underside of the DIN rail.
  • Page 27: Wall Mounting

    Wall mounting The device is grounded by the securing screw in the unpainted hole. Please note that SCALANCE X101-1AUI must be grounded over one securing screw with minimum resistance. If a device of the SCALANCE X100 product line is mounted on a non-conducting surface, it is required to install a grounding cable.
  • Page 28: Assembling The Ie Fc Standard Cable

    Installation and Maintenance 4.3 Assembling the IE FC Standard Cable Assembling the IE FC Standard Cable Assemble the IE FC RJ-45 plug 180 and the IE FC standard cable as follows For information on the assembly, please refer to the instructions that ship with the IE FC RJ-45 plug 180.
  • Page 29: Figure 4-5 Inserting The Ie Fc Rj-45 Plug 180

    Due to the closing shape and the latching with the PROFINET-compliant connector IE FC RJ-45 plug 180, the sleeve at the TP port of SCALANCE X101-1AUI ensures a robust, industry-standard node connection which provides additional strain and torsion relief of the twisted pair port.
  • Page 30: Figure 4-6 Unlatching The Rj-45 Plug

    Installation and Maintenance 4.3 Assembling the IE FC Standard Cable Removing the IE FC RJ-45 plug 180 Unlatch the IE FC RJ-45 plug 180 by slightly pressing the latching to remove the plug. Figure 4-6 Unlatching the RJ-45 plug If, for lack of space, a manual unlatching is not possible, you can also unlatch the plug with a 2.5 mm screwdriver.
  • Page 31: Assembling The Aui Cable

    Installation and Maintenance 4.4 Assembling the AUI Cable Assembling the AUI Cable Assemble or disassemble the AUI cable (drop cable) as follows The 15-pin sub-D socket has a locking. To loosen the connector, press the locking down and press it up to close it. Figure 4-7 Locking in open position Figure 4-8...
  • Page 32: Maintenance

    30 minutes before it can be turned on again. If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible.
  • Page 33: Notes On The Ce Mark

    Notes on the CE Mark Notes on the CE Mark Product Name SIMATIC NET SCALANCE X101-1AUI 6GK5101-1BX00-2AA3 EMC Directive 89/336/EEC "Electromagnetic Compatibility" Area of Application The products are designed for use in an industrial environment: Area of Application Requirements Noise emission...
  • Page 34: Notes On The Ce Mark

    5.1 Notes on the CE Mark Conformity Certificates The EU declaration of conformity is available for the responsible authorities according to the above-mentioned EU directive at the following address: Siemens Aktiengesellschaft Bereich Automatisierungs- und Antriebstechnik Industrielle Kommunikation (A&D PT2) Postfach 4848 D-90327 Nürnberg...
  • Page 35: References

    References References Sources of Information and Other Documentation 1. SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks Order numbers: 6GK1970-1BA10-0AA0 German 6GK1970-1BA10-0AA1 English 6GK1970-1BA10-0AA2 French 6GK1970-1BA10-0AA4 Italian 2. PROFINET Installation Guide can be ordered from the PROFIBUS User Organization (PNO) Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 06/2006, A2B00051526A, Product Version 03...
  • Page 37: Dimension Drawings

    Dimension Drawings Dimension Drawing Figure 7-1 Dimension drawing Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 06/2006, A2B00051526A, Product Version 03...
  • Page 38: Figure 7-2 Scalance X101-1Aui Side View

    Dimension Drawings 7.1 Dimension Drawing Figure 7-2 SCALANCE X101-1AUI side view Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 06/2006, A2B00051526A, Product Version 03...
  • Page 39 Glossary 5-4-3 Rule See “repeater rule” Attachment Unit Interface. 10 Mbps TP port (15-pin sub D) for connecting an AUI cable (drop cable). Can be implemented either as DTE (data terminal equipment) or as DCE (data carrier equipment). Is primarily used for the connection to triax segments. Autocrossover Method with which a TP port is automatically switched between MDI and MDI-X assignment to establish a connection independently of the port assignment of the device to be...
  • Page 40 Glossary Event for alarms & events: An event is any incident that could be of interest to a client. Although events can also be generated when a condition is met, it is not necessary that they are linked to a condition. Events not linked to conditions include e.g. error messages of the communication system.
  • Page 41 Glossary Redundancy Manager (RM) Switch in a ring topology which does not forward frames between its ring ports in case of functioning connections between all other switches. As soon as a connection between two switches is interrupted, the redundancy manager forwards frames between its ring ports to re-establish an intact connection between all switches.
  • Page 43 Index ATEX, 1-2 Signaling contact, 3-8 ATEX100a, 1-2 Transparent link display (green LED), 3-10 Button, 3-8 UL mark, 1-2 Connector pinout RJ-45, 3-4 SUB-D, 3-6 C-Tick mark, 1-2 Fault indicator (red LED), 3-10 Fuse, 4-10 MAU, 3-3 MDI /MDIX Autocrossover Function, 3-5 Network topology Coupling of network segments, 2-1 Port status indicator (green/yellow LEDs), 3-10...