E. IntelliFire Touch
Detailed instructions for electrical wiring and connec-
tions are provided in Section 8.
• Determine if this appliance is equipped with a Module
Reset Switch. See Section 8. Verify this switch is in
the ON position.
• Verify that the 3-Position switch on the IFT-ECM is
switched to the REMOTE position. Detailed Operating
Instructions for the IFT-ECM are provided in Section
3.K of the Owner's Manual.
3 POSITION SWITCH
LED INDICATOR
Figure 11.1 IFT-ECM
If this appliance is being upgraded to an optional Intel-
liFire Touch Remote Control, and/or optional power vent,
fan, or light kit are added as new accessory upgrade(s)
to fireplace:
1. The RC400 remote will need to be paired to the ECM.
2. Follow the installation instructions provided with the
IntelliFire Touch remote and/or accessory kit(s).
Control System Setup
®
TOP VIEW
Heat & Glo • SL-5F-IFT, SL-7F-IFT Installation Manual • 2638-980 Rev. H • 6/22
F. Fixed Glass Assembly Removal and Re-
placement
WARNING! Risk of Asphyxiation! Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOT strike, slam or scratch glass.
• DO NOT operate fireplace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• Remove decorative barrier front from fireplace and set
aside on work area.
• Pull the four glass assembly latches out of the groove
on the glass frame. Remove glass assembly from the
appliance. See Figure 11.2.
Replacing Fixed Glass Assembly
• Replace the glass assembly on the appliance. Pull out
and latch the four glass assembly latches into the groove
on the glass frame.
• Clean glass with a non-abrasive commercially available
cleaner.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer)
• Carefully set fixed glass assembly in place on fireplace.
Hold glass in place with one hand and secure glass
latches with the other hand.
• Inspect and operate all glass latches to ensure they
move freely and no obstructions are present.
• Reinstall decorative barrier front.