SYSTEM CONTROLS CONT.
9. APEX® SYSTEM CONNECTORS - Optional
connectors available via separate kit. Kit includes needed
components to power an APEX® System.
10. 12-PIN CONNECTOR
remote control equipment. The K2909-1 (12-pin to 6-pin)
adapter can be used for attaching to accessories requiring
the 6-pin connector.
11. 120/240 VAC SINGLE PHASE RECEPTACLE -
A NEMA 14-50R receptacle that provides 240 VAC or can
be split for 120 VAC single-phase auxiliary power. This
receptacle has a 50 amp rating. Refer to the AUXILIARY
POWER RECEPTACLES section in the INSTALLATION
chapter for further information about this receptacle
12. 240 VAC THREE PHASE RECEPTACLE - A
NEMA 15-50R receptacle that provides 240 VAC three-
phase auxiliary power. This receptacle has a 50 amp
rating.
13. 50A BREAKER FOR 120V/240V AND 240V
RECEPTACLES
14. 20A BREAKER FOR 120V RECEPTACLE
15. GROUND STUD - Provides a connection point for
connecting the machine case to earth ground. Refer to
MACHINE GROUNDING in the INSTALLATION section for
proper machine grounding information.
16. WELD TERMINALS - These 1/2" - 13 studs with
electrode and work cables. For positive polarity welding
the electrode cable connects to the "+" positive
terminal and the work cable connects to this "-"
negative terminal. For negative polarity welding the
work cable connects to the "+" positive terminal and
the electrode cable connects to this "-" negative
terminal.
- Used for attaching optional
B-5
OPERATION