Trane Horizon OADG Series Installation, Operation And Maintenance Manual page 11

Outdoor air unit, indirect fired gas/electric heat/air source heat pump
Table of Contents

Advertisement

Model Number Descriptions
Digit 34 — Energy Recovery
0
=
No Energy Recovery
ERV—Composite Construction 
1
=
with Bypass for Frost Protection
ERV—Composite Construction 
2
=
with Frost Protection w/VFD
ERV—Aluminum Construction 
3
=
with Bypass for Frost Protection
ERV—Aluminum Construction 
4
=
with Frost Protection w/VFD
Digit 35 — Energy Recover
Option, Purge
0
=
No Purge
1
=
Purge
Digit 36 — Energy Recover
Wheel Size
0
=
No ERV
A
=
3014
B
=
3622
C
=
4136
D
=
4634
E
=
5262
F
=
5856
G
=
6488
H
=
6876
J
=
74122
K
=
81146
L
=
86170
M =
92180
Digit 37 — Energy Recovery
Option, Rotation Sensor
0
=
No Rotation Sensor
1
=
Rotation Sensor
Digit 38 — Damper Options
1
=
100% OA 2-Position Damper
2
=
100% OA 2-Position Damper
w/RA 2-Position Damper
Modulating OA and RA Dampers 
3
=
w/Economizer
4
=
Modulating OA Damper
Digit 39 — Exhaust Dampers
0
=
No Exhaust Dampers
A
=
Gravity Dampers
B
=
Isolation Dampers
C
=
Barometric Relief Dampers
Digit 40 — Not Used
Digit 41 — Electrical Options
Terminal Block—No Factory 
0
=
Installed Disconnect
A
=
Non-Fused Disconnect
B
=
Fused Disconnect Switch
65 SCCR Electrical Rating 
C
=
w/Non-Fused Disconnect
65 SCCR Electrical Rating 
D
=
w/Fused Disconnect
65 KAIC Electrical Rating 
E
=
w/Non-Fused Disconnect
65 KAIC Electrical Rating 
F
=
w/Fused Disconnect
G
=
Dual Point Power
H
=
Dual Point Power 65 KAIC
J
=
Dual Point Power 65 SCCR
OAU-SVX006E-EN
Digit 42 — Corrosive
Environment Package
0
=
No Corrosive Package
A
=
Eco Coated Coils
B
=
S/S Interior
C
=
S/S Coil Casing
S/S Coil Casing with Eco Coated 
D
=
Coils
E
=
S/S Interior, Eco Coated Coils
F
=
Corrosion Resistant Package
Digit 43 — Outdoor Air
Monitoring
0
=
No Outdoor Air Monitoring
1
=
Airflow Probes
Digit 44 — Condenser Fan
Options
0
=
No Condenser Fans
A
=
Standard Condenser Fan
B
=
Passive Head Pressure Control
C
=
Active Head Pressure Control
ECM Condenser Fans with Active 
D
=
Head Pressure Control
ECM Condenser Fans with Active 
E
=
Head Pressure Control for Sound 
Attenuation
Digit 45 — Compressor Sound
Blankets and Sound Attenuation
0
=
No Sound Attenuation Package
A
=
Compressor Sound Blankets
B
=
Compressor Sound Blankets
with Sound Attenuation
Condenser Fans
Digit 46 — Smoke Detector
0
=
No Smoke Detector
1
=
Supply Smoke Detector
2
=
Return Smoke Detector
Supply and Return Smoke 
3
=
Detector
Digit 47 — Hailguards
0
=
No Hailguards
A
=
Hailguards
Digit 48 — Service Lights
0
=
No Service Lights
A
=
Supply Fan Section Service Light
B
=
Exhaust Fan Section Service
Light
C
=
Supply and Exhaust Fan Section
Service Light
Digit 49 — UV Lights
0
=
No UV Lights
1
=
UV Lights
Digit 50 — Not Used
Digit 51 — Unit Installation
Location
A
=
Outdoor
B
=
Indoor
Digit 52 — Convenience Outlet
0
=
No Convenience Outlet
A
=
Convenience Outlet
Digit 53 — Controls Display
0
=
No Display
1
=
TD7 Factory Installed
2
=
TD7 Remote Mounted
Digit 54 — Cooling Controls
0
=
No ReliaTel™
A
=
ReliaTel™
B
=
ReliaTel™ with BCIR Card
Digit 55 — Face and Bypass on
Indoor Coil
0
=
No Face and Bypass
Digit 56 — Thermostat
0
=
No Thermostat
1
=
Thumbwheel Thermostat
Digit 57 — Altitude
0
=
Sea Level to 1000 Feet
1
=
1001 to 2000 Feet
2
=
2001 to 3000 Feet
3
=
3001 to 4000 Feet
4
=
4001 to 5000 Feet
5
=
5001 to 6000 Feet
6
=
6001 to 7000 Feet
7
=
Above 7000 Feet
Digit 58 — Condensate
Overflow Switch
0
=
No Condensate Overflow Switch
A
=
Condensate Overflow Switch
Digit 59 — Frostat
0
=
No Frostat™
A
=
Frostat™ Installed
Digit 60 — Not Used
Digit 61 — Outdoor Coil Fluid
Type
0
=
None
1
=
Water
2
=
Ethylene Glycol
3
=
Propylene Glycol
4
=
Methanol
5
=
Other
Digit 62 — Minimum Damper
Leakage
0
=
Standard
1
=
Class 1A
Digit 63, 64, 65, 66, 67, 68, 69 —
Reserved for Future Use
11