60 Chapter 2 Breaker interface panel

Combined BIM pairs in a BIP

Table 2
Combinations of BIMs in a BIP
Shelf type
PEC of a BIP
with 2 BIMs
Passport 15000 NT6C62
Passport 20000
AP6C68

Front panel of a BIM

241-1501-200 5.2S2
When two Passport 15000 or two Passport 20000 nodes are installed in the
same NEBS 2000 frame, they share the same BIP. When a Passport 15000
and a Passport 20000 are installed in the same NEBS 2000 frame, they can
safely share the same BIP (NT6C62 or AP6C68) even though the BIMs have
different ampere ratings.
Each BIM must be matched with its mate to safely distribute power to the
Passport 15000 or 20000, and the pair must be matched to the switch as
indicated in the table "Combinations of BIMs in a BIP" (page 60).
PECs of the BIM pairs that can be installed
two or four 20-amp NT6C60PA for one or two Passport 15000s
or
two 20-amp NT6C60PA for the Passport 15000 in the lower half
of the NEBS 2000 frame and
two 25-amp AP6C67PA for a Passport 20000 in the upper half
of the NEBS 2000 frame
two or four 25-amp AP6C67PA for one or two Passport 20000s
or
two 25-amp AP6C67PA for the Passport 20000 in the lower half
of the NEBS 2000 frame and
two 20-amp NT6C60PA for a Passport 15000 in the upper half
of the NEBS 2000 frame
Since there is no visible exterior difference between the BIM faceplate of
either a Passport 15000 or 20000, you must use the part number that is labeled
on each unit.
The front panel of each breaker interface module (BIM) includes
a triangular alarm LED
a rectangular power LED

Advertisement