Checks Before Installation; Setup; Line Set Size And Refrigerant Charge - Hoshizaki KM-1301SRJZ/3 Instruction Manual

Stackable crescent cuber
Table of Contents

Advertisement

2. Checks Before Installation

1) Remove the shipping carton, tape, and packing material.
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blades move freely.

3. Setup

1) Assemble 2 sets of legs using the legs, bolts, and
nuts provided. See Fig. 13.
2) Position 1 of the plates provided between a set of
legs and the remote condenser unit, then secure
the legs to the remote condenser unit with the
bolts and nuts provided. Repeat on the other side
with the remaining set of legs.
3) The bottom of each leg has a mounting hole.
Secure the legs to the permanent site with 4 bolts
(not included).

4. Line Set Size and Refrigerant Charge

The icemaker, line set, and remote condenser unit must contain the same type
of refrigerant. Mixing of refrigerants will result in improper operation and possible
damage to the refrigeration system.
Hoshizaki
Remote
Hoshizaki
Condenser
Icemaker
Unit
KM-1301SRJZ/3 URC-14FZ 3/8"
KM-1601SRJZ/3
URC-22FZ 3/8"
KM-1900SRJZ/3
KM-2200SRJZ3
KM-2600SRJZ3 URC-26JZ
NOTICE
Line Set Size and Refrigerant Charge
Line Set
Up to 66' (20 m)
Liquid
Charge
Discharge
Line
Line
Adjustment
1/2" OD
Not
OD
Applicable
5/8" OD
Not
OD
Applicable
29
Plate
Nut
Leg
Bolt with Split
Lock Washer and
Flat Washer
Fig. 13
Line Set
Greater than 66' (20 m)
Maximum 100' (30.5 m)
Liquid
Charge Adjustment
Discharge
Line
Line
(R-404A)
3/8"
1/2" OD
Add 0.4 oz. for each
OD
foot over 66' (40 g
for each meter over
20 m). Write new
total charge on
icemaker's rating
label.
3/8"
5/8" OD
Add 0.4 oz. for each
OD
foot over 66' (40 g
for each meter over
20 m). Write new
total charge on
icemaker's rating
label.
Nut