Hoshizaki KM-1301SRJZ/3 Instruction Manual
Hoshizaki KM-1301SRJZ/3 Instruction Manual

Hoshizaki KM-1301SRJZ/3 Instruction Manual

Stackable crescent cuber

Advertisement

Instruction Manual
Stackable Crescent Cuber
Models
KM-1301SRJZ/3
KM-1601SRJZ/3
KM-1900SRJZ/3
KM-2200SRJZ3
KM-2600SRJZ3
hoshizakiamerica.com
Issued: 11-15-2021

Advertisement

Table of Contents
loading

Summary of Contents for Hoshizaki KM-1301SRJZ/3

  • Page 1 Instruction Manual Stackable Crescent Cuber Models KM-1301SRJZ/3 KM-1601SRJZ/3 KM-1900SRJZ/3 KM-2200SRJZ3 KM-2600SRJZ3 hoshizakiamerica.com Issued: 11-15-2021...
  • Page 2 Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, send an e-mail message, or write to the Hoshizaki Technical Support Department for assistance. Phone: 1-800-233-1940; (770) 487-2331 Fax: 1-800-843-1056;...
  • Page 3: Table Of Contents

    3. Remote Models KM-1301SRJZ/3 and KM-1601SRJZ/3 ........13 4. Remote Models KM-1900SRJZ/3, KM-2200SRJZ3, and KM-2600SRJZ3 .... 14 5. Remote Condenser Unit URC-14FZ (use with KM-1301SRJZ/3) ......15 6. Remote Condenser Unit URC-22FZ (use with KM-1601SRJZ/3, KM-1900SRJZ/3, KM-2200SRJZ3) and URC-26JZ (use with KM-2600SRJZ3) ........ 15 II.
  • Page 4 III. Maintenance ........................37 A. Maintenance Schedule ....................37 B. Cleaning and Sanitizing Instructions ................38 IV. Preparing the Icemaker for Periods of Non-Use ............. 42 V. Disposal ........................... 44...
  • Page 5: Important Safety Information

    Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, damage to the appliance, or damage to property. WARNING Indicates a hazardous situation which could result in death or serious injury.
  • Page 6 WARNING, continued • Children should be properly supervised around the appliance. • Do not climb, stand, or hang on the appliance or allow children or animals to do so. Serious injury could occur or the appliance could be damaged. • Do not use combustible spray or place volatile or flammable substances near the appliance.
  • Page 7: Specifications

    HI-467PSI LO-230PSI HI-427PSI LO-230PSI HI-467PSI LO-230PSI Refrigerant 404A 4 LB. 3 OZ. 404A 2 LB. 2.4 OZ. 404A Total Refrigerant Charge with Hoshizaki Remote Condenser Unit URC-14FZ: 10 LB. 5.8 OZ. Three Phase Model Number KM-1301SAJ3 KM-1301SWJ3 KM-1301SRJZ3 AC Supply Voltage...
  • Page 8: Km-1601S_J(Z)/3

    HI-467PSI LO-230PSI HI-427PSI LO-230PSI HI-467PSI LO-230PSI Refrigerant 404A 5 LB. 1.1 OZ. 404A 2 LB. 10.3 OZ. 404A Total Refrigerant Charge with Hoshizaki Remote Condenser Unit URC-22FZ: 22 LB. 15 OZ. Three Phase Model Number KM-1601SAJ3 KM-1601SWJ3 KM-1601SRJZ3 AC Supply Voltage...
  • Page 9: Km-1900S_J(Z)/3

    HI-467PSI LO-230PSI HI-427PSI LO-230PSI HI-467PSI LO-230PSI Refrigerant 404A 4 LB. 10.1 OZ. 404A 3 LB. 1.4 OZ. 404A Total Refrigerant Charge with Hoshizaki Remote Condenser Unit URC-22FZ: 21 LB. 7.9 OZ. Three Phase Model Number KM-1900SAJ3 KM-1900SWJ3 KM-1900SRJZ3 AC Supply Voltage...
  • Page 10: Km-2200S_J(Z)3

    20 AMPS Ampacity Design Pressure HI-427PSI LO-230PSI HI-467PSI LO-230PSI Refrigerant 404A 3 LB. 404A Total Refrigerant Charge with Hoshizaki Remote Condenser Unit URC-22FZ: 16 LB. 1.5 OZ. 5. KM-2600S_J(Z)3 Three Phase Model Number KM-2600SWJ3 KM-2600SRJZ3 AC Supply Voltage 208-230/60/3 208-230/60/3 Compressor 230V 11.3RLA 105LRA...
  • Page 11: Dimensions/Connections

    B. Dimensions/Connections Units: mm [in.] 1. Air-Cooled Models (SAJ/3) Rear Side Model Shown: KM-1301SAJ Model Shown: KM-1301SAJ Bottom KM-1301SAJ/3 KM-1900SAJ/3 KM-1601SAJ/3 A 695 [27-3/8] 925 [36-3/8] B 643 [25-3/8] 873 [34-3/8] C 115 [4-1/2] 130 [5-1/8] NOTICE • For all models except KM-1601SAJ/3, Model Shown: KM-1301SAJ allow 6"...
  • Page 12: Water-Cooled Models (Swj/3)

    2. Water-Cooled Models (SWJ/3) Units: mm [in.] Rear Side KM-1301/1601/1900/2200SWJ/3 Model Shown: KM-1301SWJ Model Shown: KM-1301SWJ Rear KM-1301SWJ/3 KM-1601SWJ/3 KM-1900SWJ/3 KM-2600SWJ3 KM-2600SWJ3 KM-2200SWJ3 A 695 [27-3/8] 695 [27-3/8] 925 [36-3/8] 925 [36-3/8] B 643 [25-3/8] 643 [25-3/8] 873 [34-3/8] 873 [34-3/8] C 115 [4-1/2] 115 [4-1/2] 130 [5-1/8]...
  • Page 13: Remote Models Km-1301Srjz/3 And Km-1601Srjz/3

    3. Remote Models KM-1301SRJZ/3 and KM-1601SRJZ/3 Units: mm [in.] Rear Side DATA PENDING Model Shown: KM-1301SRJZ Model Shown: KM-1301SRJZ Bottom KM-1301SRJZ/3 KM-1601SRJZ/3 A 695 [27-3/8] 695 [27-3/8] B 643 [25-3/8] 643 [25-3/8] C 115 [4-1/2] 115 [4-1/2] D DATA PENDING DATA PENDING...
  • Page 14: Remote Models Km-1900Srjz/3, Km-2200Srjz3, And Km-2600Srjz3

    4. Remote Models KM-1900SRJZ/3, KM-2200SRJZ3, and KM-2600SRJZ3 Units: mm [in.] Rear Side DATA PENDING Bottom NOTICE • Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required. •...
  • Page 15: Remote Condenser Unit Urc-14Fz (Use With Km-1301Srjz/3)

    5. Remote Condenser Unit URC-14FZ (use with KM-1301SRJZ/3) Units: mm [in.] NOTICE Allow 24" (61 cm) clearance at front and rear for proper air circulation and ease of maintenance and/or service should they be required. Rear URC-14FZ Heat of Rejection Icemaker AT 90°F (32°C)
  • Page 16: Installation And Operating Instructions

    II. Installation and Operating Instructions WARNING • The appliance must be installed in accordance with applicable national, state, and local codes and regulations. • Failure to install, operate, and maintain the appliance in accordance with this manual will adversely affect safety, performance, component life, and warranty coverage and may result in costly water damage.
  • Page 17: How To Remove Panels

    • NOTICE! Remote models must be connected to an appropriate remote condenser unit. The remote condenser units listed below are recommended. Connection to a different remote condenser unit will void the warranty unless Hoshizaki approves a different remote condenser unit for your specific application. For further details, contact your local Hoshizaki distributor.
  • Page 18: Setup

    (bin accessory) to the bottom of the ice storage bin. 2) Position the dispenser unit/ice storage bin in its permanent location. 3) If required, install an adapter kit or top kit. Contact your local Hoshizaki distributor for recommendations. 4) Level the dispenser unit/ice storage bin in both the left-to-right and front-to-rear directions.
  • Page 19: Bin Control Installation

    2. Bin Control Installation NOTICE Before operating the icemaker, the bin control must be installed. Failure to properly install the bin control could result in ice backup and icemaker damage. 1) Remove the baffle from the storage bin. 2) Remove the thumbscrew and bin control assembly from inside the icemaker. See Fig. 3. 3) Use the thumbscrew removed in the previous step and the thumbscrew included in the accessory bag to secure the bin control assembly to the bottom of the icemaker.
  • Page 20: Installation Of Upper Unit

    5) Connect the bin control cable connector to wire harness connector A coming from the control box. Note: • Wire harness has one connector (connector A) to plug into the bin control cable and another connector (connector B) for use if an upper unit is installed. •...
  • Page 21 7) Remove the bin control cable bracket from inside the upper unit. See Fig. 6. Leave the upper unit's bin control assembly in its original position. It will not be used. 8) Route lower unit wire harness connector B through the hole in the bottom of the upper unit.
  • Page 22: Electrical Connection

    E. Electrical Connection WARNING For All Models • Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or damage. •...
  • Page 23 KM-1301S_J(Z)3 KM-1601S_J(Z)3 KM-1900S_J(Z)3 KM-1601S_J(Z) KM-2200S_J(Z)3 KM-1301S_J(Z) KM-1900S_J(Z) KM-2600S_J(Z)3 WARNING WARNING WARNING ELECTRICAL CONNECTION ELECTRICAL CONNECTION ELECTRICAL CONNECTION THIS UNIT MUST BE GROUNDED THIS UNIT MUST BE GROUNDED THIS UNIT MUST BE GROUNDED Failure to properly ground or wire Failure to properly ground or wire Failure to properly ground or wire this unit could result in death, this unit could result in death,...
  • Page 24: Water Supply And Drain Connections

    • External filters, strainers, or softeners may be required depending on water quality. Contact your local Hoshizaki Certified Service Representative or local Hoshizaki distributor for recommendations. • A plumbing permit and services of a licensed plumber may be required in some areas.
  • Page 25: Icemaker

    1. Icemaker Icemaker Water Minimum Icemaker Icemaker Drain Minimum Icemaker Condensation Supply Inlet Water Supply Line Size Outlet Drain Line Size Drain Outlet 1/2" Female Pipe 3/8" Nominal ID 3/4" Female Pipe 3/4" Nominal 3/8" OD Hard Thread (FPT) Copper Water Tubing or Thread (FPT) ID Hard Pipe or Tube...
  • Page 26: Water-Cooled Condenser

    2. Water-Cooled Condenser a) Connection to an Open Drain System Condenser Water Minimum Condenser Condenser Drain Minimum Condenser Supply Inlet Water Supply Line Size Outlet Drain Line Size 1/2" Female Pipe 3/8" Nominal ID Copper 3/8" Female Pipe 3/8" Nominal ID Hard Pipe Thread (FPT) Water Tubing or Equivalent Thread (FPT)
  • Page 27 b) Connection to a Closed Loop System Condenser Water Minimum Condenser Condenser Minimum Condenser Supply Inlet Water Supply Line Size Return Outlet Return Line Size 1/2" Female Pipe 3/8" Nominal ID Copper 3/8" Female Pipe 3/8" Nominal ID Copper Thread (FPT) Water Tubing or Equivalent Thread (FPT) Water Tubing or Equivalent...
  • Page 28: Installation Of Remote Condenser Unit

    G. Installation of Remote Condenser Unit WARNING • Installation of remote condenser unit must be performed by properly trained and EPA-certified service personnel. • The remote condenser unit must be installed in accordance with applicable national, state, and local codes and regulations. •...
  • Page 29: Checks Before Installation

    Discharge Discharge Icemaker Unit Line Line Adjustment Line Line (R-404A) KM-1301SRJZ/3 URC-14FZ 3/8" 1/2" OD 3/8" 1/2" OD Add 0.4 oz. for each Applicable foot over 66' (40 g for each meter over 20 m). Write new total charge on icemaker's rating label.
  • Page 30: Line Set Installation

    5. Line Set Installation WARNING • R-404A itself is not flammable at atmospheric pressure and temperatures up to 176°F (80°C). • R-404A itself is not explosive or poisonous. However, when exposed to high temperatures (open flames), R-404A can be decomposed to form hydrofluoric acid and carbonyl fluoride both of which are hazardous.
  • Page 31 5) Remove the Schrader valve cores from the remote condenser unit service valve access ports. 6) Braze the line set copper tubes to the remote condenser unit liquid and discharge line service valves. 7) Allow the service valves to cool, then replace the Schrader valve cores. Attach the gauge manifold hoses.
  • Page 32: Electrical Connection

    6. Electrical Connection WARNING • Electrical connection must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or damage. • To reduce the risk of electric shock, make all remote condenser unit connections before connecting the icemaker power supply.
  • Page 33: Stacking Remote Condenser Unit

    3) Install a ground wire from the icemaker fan motor junction box to the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating. 4) Install line and neutral wires from the fan motor leads in the icemaker fan motor junction box to the leads in the remote condenser unit junction box.
  • Page 34: Final Checklist

    H. Final Checklist 1. Pre-Startup 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within 45°F to 100°F (7°C to 38°C) and the water temperature within 45°F to 90°F (7°C to 32°C) all year around? 3) All models except KM-1601SAJ/3: Is there at least 6"...
  • Page 35: Post-Startup

    2. Post-Startup WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/ice storage bin. 1) Has the bin control operation been confirmed? 2) Are all components, fasteners, and thumbscrews securely in place? 3) Has the end user been given the instruction manual, and instructed on how to operate the appliance and the importance of the recommended periodic maintenance? 4) Has the end user been given the contact information of an authorized service agent?
  • Page 36: Startup

    I. Startup WARNING All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. NOTICE • If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor. •...
  • Page 37: Maintenance

    III. Maintenance The appliance must be maintained in accordance with the instruction manual and labels provided. Consult with your local Hoshizaki Certified Service Representative about maintenance service. WARNING • Only qualified service technicians should service the appliance. • To reduce the risk of electric shock, do not touch the control switch with damp hands.
  • Page 38: Cleaning And Sanitizing Instructions

    B. Cleaning and Sanitizing Instructions The icemaker must be cleaned and sanitized at least once a year. More frequent cleaning and sanitizing may be required in some water conditions. WARNING • To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.
  • Page 39 10) In bad or severe water conditions, turn off the power supply, then remove, clean (cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse, and replace the cube guide, float switch, water supply tubes, spray tubes, and spray guides;...
  • Page 40 Sanitizing 14) To fill the water tank, turn the cleaning valve to the right until completely horizontal (closed). Move the control switch to the "ICE" position, then replace the front panel. After 3 min., remove the front panel, then move the control switch to the "OFF" position. 15) Remove the front insulation panel, then pour an 8.25% sodium hypochlorite solution (chlorine bleach) into the water tank.
  • Page 41 Sanitizing Rinse 3 25) Turn the cleaning valve to the right until completely horizontal (closed). Move the control switch to the "ICE" position, then replace the front panel. After 3 min., remove the front panel, then move the control switch to the "OFF" position. 26) Turn the cleaning valve to the left until completely vertical (open).
  • Page 42: Preparing The Icemaker For Periods Of Non-Use

    IV. Preparing the Icemaker for Periods of Non-Use NOTICE • When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage. • To prevent damage to the water pump seal, do not leave the control switch in the "WASH"...
  • Page 43 4) Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve. 5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring. While holding the valve open, blow out the condenser using the compressed air or carbon dioxide supply until water stops coming out.
  • Page 44: Disposal

    V. Disposal The appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulations. Refrigerant must be recovered by properly certified service personnel.
  • Page 45 618 Hwy. 74 South, Peachtree City, GA 30269 USA (P) 770.487.2331 (F) 770.487.3360 hoshizakiamerica.com 1A6569-010...